Baumer
Cable transducers
GCA3-PM – analogue, up to 4.7 m
Cable converter
Technical Specifications
Features
- Analogue interface
- Magnetic sensing method
- Operating temperature -40...+85 °C
- IP 67 protection
- M12 flange connector or cable
- Measurement lengths 2.3 m and 4.7 m
- Designed for harsh environmental conditions
- removable labels for drainage
Detailed Technical Data
TEKNIK VERILER - MEKANIK TASARIM
Resistance
EN 60068-2-6 Vibration 20 g, 10-2000 HzEN 60068-2-27 Shock 50 g, 11 ms
Material
Cable: PA12 naylon coated AISI 316 stainless steel kabloGövde: plastic
Connection
Flange connector M12, 5 pin flange connector M12, 8 pinKablo 2 m, radial
Instruction
Lütfen mounting talimatlarını dikkate alın
Cable speed
≤1 m/s
Cable ivmesi
≤10 m/s²
Cable diameter
0.7 mm
Service life
Typical 500.000 strok (load tipine connected)
Pulling kuvveti
>1.5 N (+25 °C, low sıcaklıklarda pulling kuvveti azalır)
Cable sabitleme
HalkaYükseklik: 5 mmİç diameter: 8 mmDış diameter: 15 mm
Protection EN 60529
IP 67 (elektronik bölme)IP 54 (cable input)
Subtraction kuvveti
≤8 N (+25 °C)
Measuring length
2.3 m4.7 m
Approximate weight
440 g
Operating temperature
-40...+85 °C
TECHNICAL DATA - ELECTRICAL RATINGS
Interface
Analog 0...10 V / 0.5...4.5 V / 4...20 mA
Function
Linear position geri beslemesi
Load resistor
Out/0 V between ≥3 kΩ / voltage çıkışı270 Ω / 10 VDC (500 Ω / 15 VDC)Current output
Resolution
12 bit
Supply voltage
8...30 VDC12...30 VDC
Consumption (typical)
30 mA (24 VDC, unloaded, current output)10 mA (24 VDC, unloaded, voltage output)
Emitted interference
EN 61000-6-3
Detection method
Magnetic
Measuring range
Up to 4.7 m
Linearity (typical)
±0.45 % FS (+25 °C, measurement length 2.3 m)±0.75 % FS (-40...+85 °C, measurement length 2.3 m)±0.35 % FS (+25 °C, measurement length 4.7 m)±0.65 % FS (-40...+85 °C, measurement length 4.7 m)
Short-circuit protected
Yes
Reverse polarity protection
Yes
Absolute accuracy (typical)
±0.55 % FS (+25 °C / measurement length 2.3 m)±0.85 % FS (-40...+85 °C / measurement length 2.3 m)±0.4 % FS (+25 °C / measurement length 4.7 m)±0.7 % FS (-40...+85 °C / measurement length 4.7 m)
Start-up time (typical)
power after power on ≤ 500 ms
Interference immunity
EN 61000-6-2