GCA3-PM – SAE J1939, up to 4.7 m
Baumer Cable transducers

GCA3-PM – SAE J1939, up to 4.7 m

Cable converter

Technical Specifications

Features
  • Interface: SAE J1939
  • Magnetic sensing method
  • Operating temperature: -40...+85 °C
  • Protection rating: IP 67
  • M12 flange connector or cable
  • Measurement length: 2.3 m and 4.7 m
  • Designed for harsh environmental conditions
  • removable labels for drainage
  • overvoltage protection
  • integrated tilt sensor
  • available with redundant linear and tilt sensors

Detailed Technical Data

TEKNIK VERILER - MEKANIK TASARIM

Resistance EN 60068-2-6 Vibration 20 g, 10-2000 HzEN 60068-2-27 Shock 50 g, 11 ms
Material Cable: PA12 naylon coated AISI 316 stainless steel kabloGövde: plastic
Connection Flange connector M12, 5 pinKablo 2 m, radial
Instruction Lütfen mounting talimatlarını dikkate alın
Cable speed ≤1 m/s
Cable ivmesi ≤10 m/s²
Cable diameter 0.7 mm
Service life Typical 500.000 strok (load tipine connected)
Pulling kuvveti >1.5 N (+25 °C, low sıcaklıklarda pulling kuvveti azalır)
Cable sabitleme HalkaYükseklik: 5 mmİç diameter: 8 mmDış diameter: 15 mm
Protection EN 60529 IP 67 (elektronik bölme)IP 54 (cable input)
Subtraction kuvveti ≤8 N (+25 °C)
Measuring length 2.3 m4.7 m
Approximate weight 440 g
Operating temperature -40...+85 °C

TECHNICAL DATA - ELECTRICAL RATINGS

Code Programmable
Interface SAE J1939
Function Linear position geri beslemesi
Resolution 0.1 mm (linear position)0.1 ° (slope angle)
Supply voltage 8...36 VDC
Load dump protection ISO 7637-2Test Seviyesi 4, 12 V/24 V sistemler
Consumption (typical) 30 mA (24 VDC, unloaded)60 mA (24 VDC, unloaded, yedekli)
Emitted interference EN 61000-6-3
Detection method Magnetic
Measuring range 4.7 m'ye up to (linear position)0...360° (slope sensor)
Linearity (typical) ±0.45 % FS (+25 °C, measurement length 2.3 m)±0.75 % FS (-40...+85 °C, measurement length 2.3 m)±0.35 % FS (+25 °C, measurement length 4.7 m)±0.65 % FS (-40...+85 °C, measurement length 4.7 m)±0.2° (slope angle)
Short-circuit protected Yes
Temperature coefficient 0.04 °/K (slope angle)
Programmable parameters Operating modlarıDönüş yönüÖlçeklendirmeSıfır konumu
Reverse polarity protection Yes
Absolute accuracy (typical) ±0.55 % FS (+25 °C / measurement length 2.3 m)±0.85 % FS (-40...+85 °C / measurement length 2.3 m)±0.4 % FS (+25 °C / measurement length 4.7 m)±0.7 % FS (-40...+85 °C / measurement length 4.7 m)±0.3 ° (+25 °C / slope angle)
Start-up time (typical) power after power on ≤ 500 ms
Interference immunity EN 61000-6-2

Documents

description Datasheet open_in_new Open
bolt Quick Start open_in_new Open
menu_book User Manual open_in_new Open
verified Certificates open_in_new Open
shopping_cart

Quote Cart

shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3
Canlı sohbet çok yakında aktif edilecektir.