Baumer
Cable transducers
GCA3-PT – analogue, up to 4.7 m
Cable converter – absolute
Technical Specifications
Features
- Analogue interface
- Magnetic sensing
- Operating temperature -40...+85 °C
- Protection rating IP 67
- M12 flange connector or cable
- Measurement lengths 2.3 m and 4.7 m
- Designed for harsh environmental conditions
- removable labels for drainage
Detailed Technical Data
TEKNIK VERILER - MEKANIK TASARIM
Resistance
EN 60068-2-6Titreşim 20 g, 58-2000 HzEN 60068-2-27Darbe 50 g, 11 ms
Material
Cable: PA12 naylon coated AISI 316 stainless steel kabloGövde: plastic and aluminium
Connection
Flange connector M12, 5 pinKablo 2 m, radial
Instruction
Lütfen mounting talimatlarını dikkate alın
Cable ivmesi
≤50 m/s²
Cable diameter
0.7 mm
Relative humidity
%95 non-condensing
Pulling kuvveti
>1.5 N (low sıcaklıklarda pulling kuvveti azalır)
Cable sabitleme
HalkaYükseklik: 5 mmİç diameter: 8 mmDış diameter: 15 mm
Protection EN 60529
IP 67 (housing, drenaj delikleri closed)IP 54 (cable input)
Subtraction kuvveti
≤8 N
Measuring length
2.3 m4.7 m
Approximate weight
625 g
Operating temperature
-40...+85 °C
TECHNICAL DATA - ELECTRICAL RATINGS
Code
Programmable
Interface
Analog 0...10 V / 0.5...4.5 V / 4...20 mA
Function
Linear position geri beslemesi
Load resistor
Out/0 V between >1 kΩ / voltage output 0...10 VOut/0 V between >2 kΩ / voltage output 0.5...4.5 V500 Ω / current output
Resolution
0.1 mm/step
Supply voltage
8...30 VDC14...30 VDC
Consumption (typical)
35 mA (24 VDC, w/o load)
Emitted interference
EN 61000-6-3
Start-up time
power after power on ≤ 170 ms
Detection method
Magnetic
Measuring range
Up to 4.7 m
Linearity (typical)
±0.1 % FS (measurement length 2.3 m)±0.2 % FS (measurement length 4.7 m)
Absolute accuracy (typical)
±0.1 % FS (+25 °C / measurement length 2.3 m)±0.2 % FS (+25 °C / measurement length 4.7 m)
Interference immunity
EN 61000-6-2