Baumer
Cable transducers
GCA5 – analogue, up to 4.7 m
Cable converter
Technical Specifications
Features
- Analogue interface
- Redundant version
- Magnetic sensing
- Operating temperature -40...+85 °C
- IP 67 protection
- M12 flange connector or cable
- Measurement length 2.3 m and 4.7 m
- Designed for harsh environmental conditions
- Removable rubber plugs for drainage
Detailed Technical Data
TEKNIK VERILER - MEKANIK TASARIM
Resistance
EN 60068-2-6Vibration 10 g, 10-2000 HzEN 60068-2-27Shock 50 g, 11 ms
Material
Cable: PA12 naylon coated AISI 304 stainless steel kabloGövde: plastic
Connection
Cable 2 m, radyalFlanş connector M12, 5 pin flange connector M12, 8 pin
Instruction
Lütfen mounting talimatlarını dikkate alın
Cable speed
≤1 m/s
Cable ivmesi
≤10 m/s²
Cable diameter
0.9 mm
Pulling kuvveti
>1.5 N (low sıcaklıklarda pulling kuvveti azalır)
Cable sabitleme
HalkaYükseklik: 5 mmİç diameter: 8 mmDış diameter: 15 mm
Protection EN 60529
IP 67 (housing, drenaj delikleri closed)IP 54 (cable input)
Subtraction kuvveti
≤8 N
Measuring length
2.3 m4.7 m
Approximate weight
625 g
Operating temperature
-40...+85 °C
TECHNICAL DATA - ELECTRICAL RATINGS
Interface
Analog 0...10 V / 0.5...4.5 V / 4...20 mA
Function
Linear position geri beslemesi
Linearity
±1 % FS
Load resistor
Between Out/0 V ≥3 kΩ / voltage output270 Ω at 10 VDC (500 Ω at 15 VDC) / current output
Resolution
12 bit
Supply voltage
8...30 VDC12...30 VDC
Absolute accuracy
±1.8 % FS (+25 °C)±2 % FS (-40...+85 °C)
Consumption (typical)
30 mA (24 VDC, unloaded, current output)10 mA (24 VDC, unloaded, voltage output)
Emitted interference
EN 61000-6-3
Start-up time
power after power on ≤ 500 ms
Detection method
Magnetic
Short-circuit protected
Yes
Reverse polarity protection
Yes
Interference immunity
EN 61000-6-2