Article No
11170448
Housing
ø10 x 20 mm, solid shaft, with flat
Baumer
Industrial absolute encoders
MAGRES EAM580R-SC0.7LC4.A36A1.A
Absolute encoder
Technical Specifications
Article No
11170448
Housing
ø10 x 20 mm, solid shaft, with flat
Features
- Multiturn encoder / Analogue
- E1-compliant design
- High protection rating IP 67
- High resistance to shock and vibration
- Corrosion protection CX (C5-M)
- Wire cross-section 0.5 mm²
- Teach-in input for adjustment of the measuring range
- Applicable up to PLd (ISO 13849)
Detailed Technical Data
TEKNIK VERILER - MEKANIK TASARIM
Resistance
EN 60068-2-6 Vibration 30 g, 10-2000 HzEN 60068-2-27 Shock 500 g, 1 ms
Material
Housing: dust painted steel flange: alüminyumMil: stainless steel
Connection
Cable 2 m
Shaft type
ø10 x 20 mm, flat with surface full mil
Relative humidity
95 %
Dimension (flange)
ø58 mm
Starting torque
≤2.5 Ncm (+20 °C, IP 67)
Protection EN 60529
IP 67 (mil felt seal with)
Corrosion protection
IEC 60068-2-52 Tuz sisiISO 12944-2 per spec CX (C5-M) ambient conditions for
Operating speed
≤6000 rpm
Moment of inertia
15.38 gcm²
Approximate weight
250 g
Operating temperature
-40...+85 °C (see general information)
İzin verilen shaft load
≤40 N axial≤80 N radial
TECHNICAL DATA - ELECTRICAL RATINGS
Approval
UL approval / E217823
Interface
Analog 0...10 V / 0,5...4,5 V / 4...20 mA / Resolution: 12 bit
Function
Multiturn
Response time
< 1 ms
Factory setting
360° and 10 devir (diğerleri on request)
Supply voltage
14...30 VDC
MTTFd(ISO 13849)
High (>100 yıl)Safety fonksiyonlarında only Application Note and MTTFd güvenilirlik tahminine dayanarak kullanınız (also on request ediniz).
Absolute accuracy
±0.15 ° (+20 ±15 °C) ±0.25 ° (-40...+85 °C) sensor
Consumption (typical)
20 mA (24 VDC, w/o load)
Emitted interference
EN 61000-6-4CISPR 25:2008 (30...1000 MHz)ISO 7637-2:2004** Severity level according to ECE R10 (Rev. 4)
Start-up time
power after power on ≤ 170 ms
Detection method
Magnetic
Diagnostic fonksiyonu
DATAVALID
Teach range
5°...32767 turns (multiturn)
Programmable parameters
Measurement range is teachable
Reverse polarity protection
Yes
Interference immunity
EN 61000-6-2ISO 11452-2:2004* / -5:2002*ISO 7637-2:2004*ISO 10605:2008 + Amd 1:2014 (CD ±8 kV / AD ±15 kV)* Severity level according to ECE R10 (Rev. 4)
Analog output accuracy
all measurement aralığının ±%0,5'i (-40...+85 °C)