Housing
ø6 mm, solid shaft, with flat / Slip-on coupling
Sensing Range
≤16384 / 14 bit
Baumer
Industrial absolute encoders
EAM280 - CANopen®
Absolute encoder
Technical Specifications
Housing
ø6 mm, solid shaft, with flat / Slip-on coupling
Sensing Range
≤16384 / 14 bit
Features
- Single-turn encoder / CANopen®
- Contactless measuring method, compact design
- Robust magnetic sensing
- Simple mounting, long service life
- Designed for harsh environmental conditions
- Operating temperature -40...+85 °C
- Protection against rapid temperature changes
- Redundant version available
- Protection rating IP 65 or IP 67
- Connection via M12 cable
Detailed Technical Data
TEKNIK VERILER - MEKANIK TASARIM
Resistance
EN 60068-2-6 Vibration 20 g, 10-2000 HzEN 60068-2-27 Shock 50 g, 11 ms
Material
Housing: plastic (takviyeli)Mil: stainless steel
Connection
Cable 0,3 m, radyalKablo 0,3 m, M12 with connector
Shaft type
ø6 mm, flat with surface full milGeçmeli (push-on) kaplin
Relative humidity
95 %
Service life
≥20 milyon devir(shaft load tipine bağlıdır)
Dimension (flange)
ø48 mm, housing 28,6 mm
Starting torque
≤0.5 Nm (+25 °C, variations may occur at other temperatures)
Protection EN 60529
IP 65IP 67
Operating speed
≤3000 rpm
Temperature changes
EN 60068-2-14, -40…+85 °C, 5 döngü
Approximate weight
30 g
Operating temperature
-40...+85 °C
İzin verilen shaft load
≤10 N axial≤10 N radial
TECHNICAL DATA - ELECTRICAL RATINGS
Interface
CANopen®
Function
Singleturn
Code sequence
CW: flanşa bakıldığında saat in the direction dönüşle artan değerler
Linearity
±0.25 % FS
Supply voltage
10...30 VDC
Absolute accuracy
±1 ° (+25 °C)
Consumption (typical)
14 mA (24 VDC, w/o load)
Emitted interference
EN 61000-6-3
Output stages
CAN-Bus, LV (3.3 V) compatible ISO 11898
Start-up time
power after power on ≤ 15 ms
Detection method
Magnetic
Profile conformity
CANopen® CiA communication profili DS 301, LSS profili DSP 305, device profili DS 406
Steps per revolution
≤16384 / 14 bit
Güncelleme time
20 ms
Measuring range
0...360°
Short-circuit protected
Yes
Reverse polarity protection
Yes
Interference immunity
EN 61000-6-2