Housing
ø6 mm solid shaft (synchro flange)ø10 mm solid shaft (clamping flange)
Sensing Range
1000 … 2500
Baumer
Functional safety encoders
EIL576S-S
Incremental encoder
Technical Specifications
Housing
ø6 mm solid shaft (synchro flange)ø10 mm solid shaft (clamping flange)
Sensing Range
1000 … 2500
Features
- Line driver/RS422
- Push-pull short-circuit protected
Detailed Technical Data
TEKNIK VERILER - MEKANIK TASARIM
Flange
Clamping or synchro flange
Resistance
EN 60068-2-6 Vibration 10 g, 16-2000 HzEN 60068-2-27 Shock 100 g, 6 ms
Material
Body: aluminum; Flange: aluminum
Connection
Flange connector M12, 8-pin flange connector M23, 12-pin
Shaft type
ø6 mm full mil (senkro flange)ø10 mm full mil (clamping flange)
Relative humidity
%95 non-condensing
Dimension (flange)
ø58 mm
Starting torque
≤0.015 Nm (+25 °C, IP 54)≤0.03 Nm (+25 °C, IP 65)
Protection EN 60529
IP 54 (mil felt seal without)IP 65 (mil felt seal with)
Operating speed
≤10000 rpm
Approximate weight
250 g
Rotor moment of inertia
14.5 gcm²
Operating temperature
-25...+85 °C
İzin verilen shaft load
≤20 N axial≤40 N radial
TECHNICAL DATA - ELECTRICAL RATINGS
Approval
UL approval / E63076EN 61508 per spec SIL2
Reference signal
Zero pulse 70...720° electr.
Supply voltage
24 VDC +20/-50 %
Emitted interference
EN 61000-6-4
Output stages
Line driver (Linedriver)/RS422Push-pull, short-circuit protected
Output frequency
≤150 kHz
Output signals
A 90° B + inverted
Detection method
Optical
Pulses per revolution
1000 … 2500
Consumption w/o load
≤30 mA
Reverse polarity protection
Yes
Interference immunity
EN 61000-6-2IEC 61326-3-1
Safety operating values
Encoder operating lifetime: 20 yılPFH: 1,16E-08 1/sSFF: >%90