Housing
0.2 °
Sensing Range
±0.4°
Baumer
Static tilt sensors
GIM140R – 1-dimensional, analogue
Tilt sensor
Technical Specifications
Housing
0.2 °
Sensing Range
±0.4°
Features
- Size 48 mm
- Analogue interface
- MEMS capacitive measuring principle
- 1-dimensional measurement range: 0...360°
- Aluminium housing
- Protection rating IP 67/IP 69K
- UL approval
- Connection cable
- Teach-in input for zero position adjustment
Detailed Technical Data
TEKNIK VERILER - MEKANIK TASARIM
Resistance
EN 60068-2-6Vibration 10 g, 10-2000 HzEN 60068-2-27Shock 50 g, 11 ms
Material
Body: aluminum, anodized
Connection
Cable 0.3 m, radial
Protection EN 60529
IP 67 / IP 69K
Corrosion protection
ISO 9227:2017 salt mist according to ISO 12944-6:1998 C5-M (CX)
Dimensions W x H x L
48 x 14 x 45 mm
Approximate weight
50 g
Operating temperature
-40...+85 °C
TECHNICAL DATA - ELECTRICAL RATINGS
Approval
UL approval / E217823
Interface
Analog (4...20 mA / 0.5...4.5 V / 0...10 V)
Load resistor
Between Out/0 V ≥3 kΩ / voltage output270 Ω at 10 VDC (500 Ω at 15 VDC) / current output
Resolution
0.2 °
Supply voltage
8...30 VDC12...30 VDC
Consumption (typical)
8 mA (24 VDC, no load, voltage output) 12 mA (no load, current output)
Emitted interference
EN 61000-6-3
Detection method
MEMS technology
Diagnostic fonksiyonu
Range outer diagnostic
Accuracy (+25 °C)
±0.4°
Measuring range
0...30°, 0...60°, 0...90°, 0...120°, 0...180°, 0...270°, 0...360°
Short-circuit protected
Yes
Programmable parameters
Preset
Reverse polarity protection
Yes
Interference immunity
EN 61000-6-2