Article No
11237419
Housing
4 ... 20 m / AIO-Link
Sensing Range
Delivery time on request
Baumer
Measurement amplifiers
DAB10-AI
Measurement amplifier
Technical Specifications
Article No
11237419
Housing
4 ... 20 m / AIO-Link
Sensing Range
Delivery time on request
Features
- 4 ... 20 mA current output
- Analogue force measurement with digital IO-Link interface
- Individual and application-specific parameterisation
Detailed Technical Data
Genel veriler
Repeatability
< 0.01 %
Output Signal
4 ... 20 mA, IO-Link
Temperature effect zero
< 0.01 % / 10K
Non-linear deviation
< 0.04 %
Mechanical Data
Housing material
Aluminum, 6060, chemically passivated
Control on the side electrical connection
M12, 5 pin, male
Sensor on the side electrical connection
M8, 4 pin, female thread
Electrical Data
SNR @1.0 mV/V
> 75 dB
Supply voltage
18 ... 30 VDC
Current consumption
< 40 mA
Resolution ADC
24 bit
Resolution DAC
14 bit
Short-circuit protection
Yes
Cut-off frequency (3 db)
1 kHz
Reverse polarity protection
Yes
Örnekleme speed input
8 kS/s
Max.. output range
0 ... 22 mA
Örnekleme speed analog output
8 kS/s
IO-Link Interface
SIO-mode
Yes
Baud rate
230,4 kbaud (COM3)
Cycle time
≥ 1 ms
IO-Link port type
Class A
IO-Link version
1.1
Process data length
32 bit
Process data (cyclic)
Proses DeğeriÖlçek üsteliSSC 1SSC 2KaliteAlarm
ENVIRONMENTAL CONDITIONS
Shock IEC 60068-2-27
50 g / 11 ms, 100 g / 6 ms
Random IEC 60068-2-64
20 ... 1000 Hz: 0.1 g²/Hz
Vibration IEC 60068-2-6
10 … 57 Hz: 1.5 mm p-p, 58 ... 2000 Hz: 10 g
Depolama temperature range
-40 ... 85 °C
Protection class EN 60529, ISO20653
IP 65
Operating temperature range
-40 ... 85 °C
IO-Link Features
Additional data
Diagnostic verisiHata detection
Additional fonksiyonlar
Low passing filtreTepe value belleğiÖrnekle and tutİki dijital switching point (SSC)Uzaktan çalıştırma
Parameterizable
Proses girişiBirim (N, kg, µm/m) seçilebilirTeach-in Ofset/DaraBilinen kuvvete korelasyonAnalog output signalÇıkış range analog sinyalAlarm state analog signal/O fonksiyonları selectable
COMPLIANCE AND APPROVALS
Conformity
CEUL
Electrical Data (Bridge)
Signal area
± 3.8 mV/V
Power Supply
2.5 VDC
Köprü direnci
≥ 350 Ω