Article No
11122316
Housing
≤ 0.1 % FS
Sensing Range
ISO 2852 (Tri-Clamp) Ø 34.0
Baumer
Pressure sensors
PBMH-25B15RA15657F02000
Pressure sensor
Technical Specifications
Article No
11122316
Housing
≤ 0.1 % FS
Sensing Range
ISO 2852 (Tri-Clamp) Ø 34.0
Features
- Fully autoclavable pressure sensor for standard sterilisation processes
- High temperature resistance for SIP and CIP processes
- Surface roughness of the process connection Ra ≤ 0.8 to meet the highest hygiene requirements
- Fully welded and compact design to prevent residuals during washdowns
- Excellent active temperature compensation for increased process stability
- External programming of zero point and span via the FlexProgrammer 9701
Detailed Technical Data
Process connection
Connection variants
ISO 2852 (Tri-Clamp), DN 21.3, Ø 34.0
Performance Features
Pressure type
Relative (gauged)
Long term stability
≤ 1 mbar
Measuring range
0 … 1 bar
Max.. measurement error
± 0.1 % FSR zero point and range error, non-linearity (terminal base to the line according to), hysteresis and non-repeatability includes (EN 61298-2)
Temperature coefficient
≤ 0.03 % FSR/10 K , measuring span≤ 0.03 % FSR/10 K , zero point
Yükselme time (%10 … %90)
≤ 5 ms
Max.. measuring rate (turndown)
5 : 1
Standard error of measurement (BFSL)
± 0.04 % FSR linear olmama, hysteresis and non-repeatability includes (BFSL per spec)
Compensated temperature range
-10 … 85 °C