Housing
≤ 0.25 - 0.3 % FS≤ 0.5 - 0.7 % FS
Baumer
Pressure sensors
PP20S industrial
Pressure measurement
Technical Specifications
Housing
≤ 0.25 - 0.3 % FS≤ 0.5 - 0.7 % FS
Features
- Suitable for all types of industrial applications
- Front-flush pressure connection available to meet the requirements of water applications and high-viscosity media
- Standard operating range from -1 to 400 bar
- High accuracy over a wide temperature range (-40 … 125 °C)
- active temperature compensation
- robust and compact stainless steel housing for harsh environmental conditions
- ceramic measurement cell for resistance to abrasion
- relative pressure and vacuum measurement
- programmable via the FlexProgrammer 9701
Detailed Technical Data
Process connection
Connection variants
"Ölçü çizimleri" see section
Wetted parts material
AISI 304 (1.4301)AISI 316L (1.4404)Ceramic, 96% AL2O3NBR, optionalEPDM, optionalFKM, optional, contalar gerektirir a minimum ortam temperature of -20 °C and a minimum orta temperature of -25 °CFVMQ, optional
Performance Features
Pressure type
Relative (gauged)
Long term stability
≤ 0.2 % FSR/a
Min.. measuring span
0.25 bar
Measuring range
-1 … 400 bar
Basamak response time
< 3 ms
Max.. measurement error
± 0.3 % FSR± 0.5 % FSR± 1.0 % FSR± 3.0 % FSR zero point and range error, non-linearity (terminal base to the line according to), hysteresis and non-repeatability includes (EN 61298-2)
Temperature coefficient
≤ 0.05 % FSR/10 K , measuring span≤ 0.05 % FSR/10 K , zero point
Power-on time
< 50 ms
Max.. measuring rate (turndown)
5 : 1
Standard error of measurement (BFSL)
± 0.12 % FSR± 0.2 % FSR± 0.4 % FSR± 1.2 % FSR linear olmama, hysteresis and non-repeatability includes (BFSL per spec)
Max.. measuring range width
400 bar
Compensated temperature range
-10 … 60 °C