Housing
≤ 0.1 % FS≤ 0.25 - 0.3 % FS
Sensing Range
BHC 3 / A DN 38 (B01)BHC 3 / A DN 76 (B02)ISO 2852 (Tri-Clamp), DN 25; 33.7; 38, Ø 50.5 (C04)ISO 2852 (Tri-Clamp), DN 25, Ø 50.5 (C03)Tri-Clamp DN 3/4" Ø 24.9 (C01)ISO 2852 (Tri-Clamp), DN 40; 51, Ø 64.0 (C05)ISO 2852 (Tri-Clamp) Ø 34.0 / DIN 11864-3-A BKS (Aseptic Clamp) DN25 Ø50.5 (H41)
Baumer
Pressure sensors
PBMH autoclavable - Configurator
Pressure sensor
Technical Specifications
Housing
≤ 0.1 % FS≤ 0.25 - 0.3 % FS
Sensing Range
- BHC 3 / A DN 38 (B01)BHC 3 / A DN 76 (B02)ISO 2852 (Tri-Clamp), DN 25
- 33.7
- 38, Ø 50.5 (C04)ISO 2852 (Tri-Clamp), DN 25, Ø 50.5 (C03)Tri-Clamp DN 3/4" Ø 24.9 (C01)ISO 2852 (Tri-Clamp), DN 40
- 51, Ø 64.0 (C05)ISO 2852 (Tri-Clamp) Ø 34.0 / DIN 11864-3-A BKS (Aseptic Clamp) DN25 Ø50.5 (H41)
Features
- Fully autoclavable pressure sensor for standard sterilisation processes
- High temperature resistance for SIP and CIP processes
- Surface roughness of the process connection Ra ≤ 0.8 to meet the highest hygiene requirements
- Fully welded and compact design to prevent residuals during washdowns
- Excellent active temperature compensation for increased process stability
- External programming of zero point and span via the FlexProgrammer 9701
Detailed Technical Data
Process connection
Connection variants
"Ölçü çizimleri" see section
Wet part material, membrane
AISI 316L (1.4435)
Performance Features
Pressure type
AbsoluteRelative (gauged)
Long term stability
≤ 0.1 % FSR/a , measuring range > 1 bar≤ 1 mbar , measuring range ≤ 1 bar
Min.. measuring span
0.4 bar
Measuring range
-1 … 40 bar
Basamak response time
≤ 5 ms
Max.. measurement error
± 0.1 % FSR± 0.25 % FSR zero point and range error, non-linearity (terminal base to the line according to), hysteresis and non-repeatability includes (EN 61298-2)Turndown for, this value applied turndown at a ratio of multiply
Temperature coefficient
≤ 0.03 % FSR/10 K , measuring span≤ 0.03 % FSR/10 K , zero point
Max.. measuring rate (turndown)
5 : 1
Standard error of measurement (BFSL)
± 0.04 % FSR± 0.1 % FSR linear olmama, hysteresis and non-repeatability includes (BFSL per spec)Turndown for, this value applied turndown at a ratio of multiply
Max.. measuring range width
40 bar
Compensated temperature range
-10 … 85 °C