Housing
≤ 0.1 % FS≤ 0.25 - 0.3 % FS
Sensing Range
G 1/2 A DIN EN ISO 1179-2 (3852-E) (G51)G 1/2 A DIN EN ISO 1179-2 (G51) bore Ø 10 mm / G 1/2 B EN 837-1 / G 1/4 A DIN EN ISO 1179-2 (3852-E) (G50)G 1/4 A ISO 228-1 female threadG 1/4 B EN 837-11/2-14 NPT (N02)1/4-18 NPT (N01)
Baumer
Pressure sensors
PBMN low pressure - Configurator
Pressure sensor
Technical Specifications
Housing
≤ 0.1 % FS≤ 0.25 - 0.3 % FS
Sensing Range
G 1/2 A DIN EN ISO 1179-2 (3852-E) (G51)G 1/2 A DIN EN ISO 1179-2 (G51) bore Ø 10 mm / G 1/2 B EN 837-1 / G 1/4 A DIN EN ISO 1179-2 (3852-E) (G50)G 1/4 A ISO 228-1 female threadG 1/4 B EN 837-11/2-14 NPT (N02)1/4-18 NPT (N01)
Features
- Excellent accuracy and active temperature compensation for precise pressure measurements
- Measurement range from -0.1 ... 0.1 bar up to 0 ... 40 bar
- Robust stainless steel housing suitable for a wide range of applications
- Ex certification available as an option (4 ... 20 mA output)
- Absolute pressure, relative pressure and vacuum measurement
- External programming of zero point and span using the FlexProgrammer 9701
Detailed Technical Data
Process connection
Connection variants
"Ölçü çizimleri" see section
Wetted parts material
AISI 316L (1.4404)
Wet part material, membrane
AISI 316L (1.4435)
COMPLIANCE AND APPROVALS
Explosion protection
ATEX II 1/2G Ex ia IIC T4/T6 Ga/GbATEX II 1D Ex ia IIIC T (200) 107 °C IP6X DaATEX II 1G Ex ia IIC T4/T6 Ga
Performance Features
Pressure type
AbsoluteRelative (gauged)
Long term stability
≤ 0.1 % FSR/a , measuring range > 1 bar≤ 1 mbar , measuring range ≤ 1 bar
Min.. measuring span
0.1 bar
Measuring range
-1 … 40 bar
Max.. measurement error
± 0.1 % FSR± 0.25 % FSR zero point and range error, non-linearity (terminal base to the line according to), hysteresis and non-repeatability includes (EN 61298-2)Turndown for, this value applied turndown at a ratio of multiply
Temperature coefficient
≤ 0.03 % FSR/10 K , measuring span≤ 0.03 % FSR/10 K , zero point
Yükselme time (%10 … %90)
≤ 5 ms
Max.. measuring rate (turndown)
5 : 1
Standard error of measurement (BFSL)
± 0.04 % FSR± 0.1 % FSR linear olmama, hysteresis and non-repeatability includes (BFSL per spec)
Max.. measuring range width
40 bar
Compensated temperature range
-40 … 85 °C