Housing
≤ 0.5 - 0.7 % FS≥ 1 % FS
Sensing Range
G 1 A hygienic / G 1/2 A hygienic (A03)ISO 2852 (Tri-Clamp), DN 25, Ø 50.5 (C03)G 1/2 A DIN EN ISO 1179-2 (3852-E) (G51)ISO 2852 (Tri-Clamp), DN 40; 51, Ø 64.0 (C05)DIN 11851 (dairy pipe connection), DN 50 / DIN 11851 (dairy pipe connection), DN 40 / Varivent® DN 25; 1" (Type F), Ø 50 / Varivent® DN 32 … 125; 1 1/2" … 6" (Type N), Ø 68 (V02)
Baumer
Pressure sensors
PP20H - Configurator
Pressure sensor
Technical Specifications
Housing
≤ 0.5 - 0.7 % FS≥ 1 % FS
Sensing Range
- G 1 A hygienic / G 1/2 A hygienic (A03)ISO 2852 (Tri-Clamp), DN 25, Ø 50.5 (C03)G 1/2 A DIN EN ISO 1179-2 (3852-E) (G51)ISO 2852 (Tri-Clamp), DN 40
- 51, Ø 64.0 (C05)DIN 11851 (dairy pipe connection), DN 50 / DIN 11851 (dairy pipe connection), DN 40 / Varivent® DN 25
- 1" (Type F), Ø 50 / Varivent® DN 32 … 125
- 1 1/2" … 6" (Type N), Ø 68 (V02)
Detailed Technical Data
IO-Link Interface
SIO-mode
Yes
Baud rate
38,4 kbaud (COM2)
Dual Channel
IO-Link / AnalogueAnalogue / SIO Mode
Device profile
Smart Sensor Profile
IO-Link port type
Class A
IO-Link version
1.1
Process data (cyclic)
Basınç or sıcaklıkŞalter durumuUyarı durumuÖlçekleme factor
Diagnostic data (acyclic)
Ortam basıncıCPU sıcaklığıBirim sıcaklığıÇalışma time (power açıldığından beri)
Adjustable data (acyclic)
Offset settingsSwitch parametersMeasuring mode
Process connection
Connection variants
G 1 A hygienicG 1/2 A DIN 3852-EG 1/2 A hygienicISO 2852 (Tri-Clamp), DN 25, Ø 50.5 (BCID: C03)ISO 2852 (Tri-Clamp), DN 40; 51, Ø 64.0Varivent® DN 25; 1" (Type F), Ø 50Varivent® DN 32 … 125; 1 1/2" … 6" (Type N), Ø 68DIN 11851, DN 40DIN 11851, DN 50DIN 11864-1-A (aseptic screwed union), DN40DIN 11864-1-A (aseptic screwed union), DN50
Wetted parts material
AISI 316L (1.4404)
Wet part material, membrane
AISI 316L (1.4435)
Performance Features
Pressure type
AbsoluteRelative (gauged)
Long term stability
≤ 0.2 % FSR/a
Min.. measuring span
0.4 bar
Measuring range
-1 … 40 bar
Max.. measurement error
± 0.5 % FSR± 1.0 % FSR , 0 … 0.4 barSıfır point and range error, non-linearity (terminal base to the line according to), hysteresis and non-repeatability includes (EN 61298-2)
Temperature coefficient
≤ 0.2 % FSR/10 K , measuring span≤ 0.2 % FSR/10 K , zero point
Yükselme time (%10 … %90)
≤ 20 ms
Standard error of measurement (BFSL)
± 0.2 % FSR± 0.5 % FSR , 0 … 0.4 barDoğrusal olmama, hysteresis and non-repeatability includes (BFSL per spec)
Max.. measuring range width
40 bar
Compensated temperature range
-20 … 125 °C