Pressure sensors
PP54 - Configurator
Pressure sensor
Technical Specifications
Housing
≤ 0.25 - 0.3 % FS≤ 0.5 - 0.7 % FS
Sensing Range
1/4-18 NPT (N01)G 1/2 A DIN EN ISO 1179-2 (3852-E) (G51)G 1/2 B EN 837-1 / G 1/4 A DIN EN ISO 1179-2 (3852-E) (G50)G 1/4 B EN 837-1 / Front-flush G 3/4 A DIN EN ISO 1179-2 (3852-E) (G57)Front-flush G 1 A DIN EN ISO 1179-2 (3852-E) (G54)Front-flush G 1/2 A DIN EN ISO 1179-2 (3852-E) (G51)
Features
- All standard industrial connections available
- dual-channel IO-Link output in parallel with 4...20 mA
- space-saving installation
- relative pressure and vacuum measurement
- easy parameterisation via display, IO-Link and FlexProgram
- rotatable display with 28 steps over 315°
Detailed Technical Data
IO-Link Interface
SIO-mode
Yes
Baud rate
38,4 kbaud (COM2)
Dual Channel
IO-Link / SIO Mode
Device profile
Smart Sensor Profile
Dual Channel 2
Analogue / SIO Mode
Cycle time
≥ 4 ms
IO-Link port type
Class A
IO-Link version
1.1
Process data length
48 bit
Process data (cyclic)
PressureSwitch stateState of alert
Diagnostic data (acyclic)
Measuring cell temperatureCPU temperatureOperation
Adjustable data (acyclic)
Offset settings, Switch parameters, Current output limit values, Display configuration, Tags, Password for access
Process connection
Connection variants
"Ölçü çizimleri" see section
Wetted parts material
AISI 304 (1.4301)AISI 316L (1.4404)Ceramic, 96% AL2O3NBR, optionalEPDM, optionalFKM, optionalFVMQ, optional
Performance Features
Pressure type
Relative (gauged)
Long term stability
≤ 0.2 % FSR/a
Min.. measuring span
0.4 bar, standard configuration
Measuring range
-1 … 200 bar"Operating conditions" see section
Max.. measurement error
± 0.3 % FSR± 0.5 % FSR zero point and range error, non-linearity (terminal base to the line according to), hysteresis and non-repeatability includes (EN 61298-2)Turndown for, this value applied turndown at a ratio of multiply
Temperature coefficient
≤ 0.1 % FSR/10 K , kompanze -ed temperature aralığında≤ 0.2 % FSR/10 K"Operating conditions" see section
Power-on time
< 600 ms @ 24 V
Max.. measuring rate (turndown)
5 : 1
Standard error of measurement (BFSL)
± 0.12 % FSR± 0.2 % FSR linear olmama, hysteresis and non-repeatability includes (BFSL per spec)Turndown for, this value applied turndown at a ratio of multiply
Max.. measuring range width
200 bar, standard configuration
Compensated temperature range
-10 … 70 °C