Housing
Continuous level measurement
Sensing Range
Flush membrane / ATEX
Baumer
Level sensors
PBMN flush - Configurator
Pressure sensor
Technical Specifications
Housing
Continuous level measurement
Sensing Range
Flush membrane / ATEX
Detailed Technical Data
Process connection
Connection variants
"Ölçü çizimleri" see section
Wetted parts material
AISI 316L (1.4404)
Wet part material, membrane
AISI 316L (1.4435)
COMPLIANCE AND APPROVALS
Explosion protection
ATEX II 1/2G Ex ia IIC T4/T6 Ga/GbATEX II 1/2G Ex ia IIC T3/T4/T6 Ga/GbATEX II 1D Ex ia IIIC T (200) 107 °C IP6X DaATEX II 1G Ex ia IIC T4/T6 GaATEX II 1G Ex ia IIC T3/T4/T6 Ga
Performance Features
Pressure type
AbsoluteRelative (gauged)
Long term stability
≤ 0.1 % FSR/a , measuring range > 1 bar≤ 1 mbar , measuring range ≤ 1 bar
Min.. measuring span
0.1 bar
Measuring range
-1 … 400 bar
Max.. measurement error
± 0.1 % FSR± 0.25 % FSR zero point and range error, non-linearity (terminal base to the line according to), hysteresis and non-repeatability includes (EN 61298-2)Turndown for, this value applied turndown at a ratio of multiply
Temperature coefficient
≤ 0.03 % FSR/10 K , measuring span≤ 0.03 % FSR/10 K , zero point
Yükselme time (%10 … %90)
≤ 5 ms
Max.. measuring rate (turndown)
5 : 1
Standard error of measurement (BFSL)
± 0.04 % FSR± 0.1 % FSR linear olmama, hysteresis and non-repeatability includes (BFSL per spec)
Max.. measuring range width
400 bar
Compensated temperature range
-40 … 85 °C