Housing
Continuous level measurement
Sensing Range
Features measuring heights down to 200 mm, extremely short response time for highly dynamic processes
Baumer
Level sensors
CombiLevel PLP70S
Level sensor
Technical Specifications
Housing
Continuous level measurement
Sensing Range
Features measuring heights down to 200 mm, extremely short response time for highly dynamic processes
Features
- Suitable for a wide range of homogeneous process media, particularly those with low conductivity > 5 µS/cm
- Wetted parts made of corrosion-resistant stainless steel or PEEK
- Compact design
- Defined empty registration
- LED fill level indicator
- Not affected by strong adhesion
- Configurable measuring range
Detailed Technical Data
Output signal
Output type
PNPNPNDijital (push-pull)
Output Signal
4 … 20 mA
Switching mantığı
High Active, Low Active
IO-Link Interface
SIO-mode
Yes
Baud rate
38,4 kbaud (COM2)
Device profile
Smart Sensor Profile
IO-Link port type
Class A
IO-Link version
1.1
Process data (cyclic)
Proses DeğeriCihaz State
Adjustable data (acyclic)
Sensor AyarıŞalter parametreleriAnalog Output Signal AyarıAnalog Output Signal limitleri (Minimum, Maksimum, Alarm)
Process connection
Wetted parts material
AISI 316L (1.4404)PEEK Natura
Wet part surface pürüzlülüğü
Ra ≤ 0.8 µm
COMPLIANCE AND APPROVALS
Safety
cULus listeli, E527512
EMC Emission
EN 61326
EMC Immunity
EN 61326
Performance Features
Damping
≤ 60 s
Repeatability
0.2 % FSR , çubuk length for ≥ 500mm1 mm , çubuk length for < 500mm
Measuring principle
Potentiometric level measurement
Measuring range
200 … 3000 mm
Media characteristics
≥ 5 µS/cm
Basamak response time, T90
≤ 100 ms
Max.. measurement error (BFSL)
± 1 % FSR ± 2 mm , for media conductivity ≥ 50 µS/cm± 3 % FSR ± 2 mm , for media conductivity < 50 µS/cm