Housing
ISO 2852 (Tri-Clamp) / DIN 32676-B / BS 4825-3 (ASME BPE) / DIN 32676-C / SMS 1145 male thread, COP / DIN 11851 (dairy pipe connection) / DIN EN 10357 series A (DIN 11850-2), weldable pipe end
Sensing Range
2 x M16x1.5 cable gland, stainless steel / 1 x M12-A, 5-pin + 1 x M12-A, 8-pin, stainless steel connector
Baumer
Flow measurement
CombiFlow PF75H
Flow sensor
Technical Specifications
Housing
ISO 2852 (Tri-Clamp) / DIN 32676-B / BS 4825-3 (ASME BPE) / DIN 32676-C / SMS 1145 male thread, COP / DIN 11851 (dairy pipe connection) / DIN EN 10357 series A (DIN 11850-2), weldable pipe end
Sensing Range
2 x M16x1.5 cable gland, stainless steel / 1 x M12-A, 5-pin + 1 x M12-A, 8-pin, stainless steel connector
Features
- Volume and velocity measurement in a single sensor
- Particularly precise and stable measurements with accuracies to 0.2%
- For media with conductivity > 5 µS/cm in closed systems
- Measurement range 0 … 280 m³/h with tube diameters DN 3 … 100
- Hygienic design compliant with 3-A and FDA standards
- No energy loss thanks to the absence of a constriction in the continuous measuring tube
- CombiView DFON graphic display optionally available and programmable via touch screen or BCP software
Detailed Technical Data
Output signal
Interface (optional)
Hart
Process Conditions
Process temperature
-20 … 100 °C-20 … 150 °C , remote versiyon for water, other media on on request
SIP/CIP compatibility
< 30 dk, general as, ortam sıcaklığında -e up to 130 °C
Environmental Conditions
Protection degree (EN 60529)
IP 65IP 67
Process connection
Process Connection
ISO 2852 (Tri-Clamp) DIN 11851 (milk line connection) BS 4825-3 SMS 1145 male thread DIN EN 10357 serisi A (DIN 11850-2), kaynaklanabilir boru ucu
Wetted parts material
PTFE, Accofal 3G54, optional
Wet part material, astar
PTFE
Wet part material, seal
FKM
Wet part material, elektrotlar
AISI 316L (1.4404)
Wet part surface pürüzlülüğü
Ra ≤ 0.8 µm
COMPLIANCE AND APPROVALS
EMC
IEC 61326-1EN 61326-1
Hygiene
3-A (28-06)
Performance Features
Damping
0.2 … 1000 s
Repeatability
≤ 0.1 % o. r.
Sampling interval
≤ 200 ms
Max.. flow speed
10 m/s
Measuring principle
Electromagnetic flow measurement
Min.. measuring span
0 … 10.3 l/h
Basamak response time
≤ 400 ms
Media characteristics
≥ 5 µS/cm
Max.. measurement error
± 0.5 % o. r.± 0.2 % o. r. , optional
Measuring range, flow
0 … 288 m3/h0.1 … 10 m/s
Max.. measuring rate (turndown)
1 : 1000