Housing
DIN 228-1 male thread / NPT male thread
Sensing Range
M12-A, 5-pin, stainless steel connector / 1 x M12-A, 5-pin + 1 x M12-A, 8-pin, stainless steel connector / 2 x M16x1.5 cable gland, stainless steel / 2 x M20x1.5 cable gland, stainless steel
Baumer
Flow measurement
CombiFlow PF75S
Flow sensor
Technical Specifications
Housing
DIN 228-1 male thread / NPT male thread
Sensing Range
M12-A, 5-pin, stainless steel connector / 1 x M12-A, 5-pin + 1 x M12-A, 8-pin, stainless steel connector / 2 x M16x1.5 cable gland, stainless steel / 2 x M20x1.5 cable gland, stainless steel
Features
- Volume and velocity measurements in a single sensor
- Precise and stable measurements with accuracies to 0.2%
- For media with conductivity > 5 µS/cm in closed systems
- Measurement range 0 … 4500 m³/h for pipe diameters DN 3 … 400
- Robust and resistant to temperature fluctuations
- No energy loss thanks to the absence of a constriction in the continuous measuring tube
- CombiView DFON graphic display optionally available and programmable via touch screen or BCP software
Detailed Technical Data
Process Conditions
Process temperature
Konfigürasyona according to
Environmental Conditions
Protection degree (EN 60529)
IP 65IP 67
Process connection
Wetted parts material
PTFE, Accofal 3G54, optional
Wet part material, astar
Konfigürasyona according to
Wet part material, seal
Konfigürasyona according to
Wet part material, elektrotlar
Konfigürasyona according to
Wet part surface pürüzlülüğü
Ra ≤ 0.8 µm
COMPLIANCE AND APPROVALS
EMC
IEC 61326-1EN 61326-1
Performance Features
Damping
0.2 … 1000 s
Repeatability
≤ 0.1 % o. r.
Sampling interval
≤ 200 ms
Max.. flow speed
10 m/s
Measuring principle
Electromagnetic flow measurement
Min.. measuring span
0 … 0.01 m3/h
Basamak response time
≤ 400 ms
Media characteristics
≥ 5 µS/cm
Max.. measurement error
± 1.0 % o. r.± 0.5 % o. r. , optional± 0.2 % o. r. , optional
Measuring range, flow
0 … 4500 m3/h0.1 … 10 m/s
Max.. measuring rate (turndown)
1 : 1000