Housing
≤ 25 bar
Sensing Range
-20...140°C
Baumer
Liquid analysis
CombiLyz AFI5
Conductivity sensor
Technical Specifications
Housing
≤ 25 bar
Sensing Range
-20...140°C
Features
- Separated sensor
- Ideal for confined spaces and strong vibrations
- All wetted parts made of PEEK
- Compact, food-safe, hygienic design
- Complies with 3-A sanitary standards, FDA-compliant, EHEDG-certified
- Available with HART® communication protocol
- Available with IO-Link communication interface
Detailed Technical Data
CABLE (AFI5)
Material
Material: PUR
Temperature
-40 … 80 °C
Cable lengths
10.0 m5.0 m2.5 m
HART® Interface
Protocol
HCF standard, Rev.7
Properties
Universal commandsCommon-practice commandsConductivity device family commandsDevice Specific CommandsFor more information please see ‚HART Field Device Specification‘
IO-Link Interface
SIO-mode
Yes
Baud rate
38,4 kbaud (COM2)
Device profile
Smart Sensor Profile
Cycle time
≥ 8.4 ms
IO-Link version
1.1
Process data length
128 bit
Process data (cyclic)
Switch durumuSinyal analog output 1Sinyal analog output 2TemperatureBirim sıcaklığıİletkenlikKonsantrasyonActual measuring range
Process Conditions
Process pressure
≤ 25 bar
Process temperature
-20 … 140 °C , sürekli140 … 150 °C , max.. t < 1 h
Environmental Conditions
Protection degree (EN 60529)
IP67IP69K , suitable cable with
Process connection
Connection variants
G 1 A hygienic
Wetted parts material
PEEK Natura
Wet part surface pürüzlülüğü
Ra ≤ 0.8 µm
COMPLIANCE AND APPROVALS
EMC
EN 61326-1
Safety
cULus listeli, E491206
Hygiene
3-A (74-07)EHEDG EL Class IFDA (21 CFR 177.2415)
Performance Features - Temperature
Temperature
Serbest programmable range
Measuring range
-20 … 150 °C
Max.. measurement error
± 1.5 K0.3 K , 20 … 50 °C
Termal response time, T90
≤ 15 s
Performance Features - Conductivity
Conductivity
14 selectable ranges
Repeatability
< 0.5 % FSR , > 1 mS/cm
Örnekleme time
≤ 0.4 s
Min.. measuring span
500 µS/cm
Referans temperature
25 °C , adjustable
Max.. measurement error
± 1.0 % FSR , 0 … 1 mS/cm to 0 … 500 mS/cm± 1.5 % FSR , 0 … 1000 mS/cm± 1.5 % FSR , 0 … 500 µS/cm
Temperature compensation
0.0 … 5.0 % FSR/K , adjustable
Basamak response time, T90
≤ 2.0 s
Min.. measurable conductivity
50 µS/cm
Max.. measuring range width
1000 mS/cm
Compensated temperature range
-20 … 150 °C
Performance Features - Concentration
Concentration
IO-Link and FlexProgram with programmable
Customer defined media
Customer defined (30 point lookup table)
Factory set media (available from FlexProgram)
0 … 25 % by weight , HNO3 (nitrik asit)36 … 82 % by weight , HNO3 (nitrik asit)0 … 12 % by weight , NaOH (kostik soda)25 … 50 % by weight , NaOH (kostik soda)