PT55H
Housing Sensor lengthsee "Ordering information" sectionOther lengths ≤ 3000 mm on request
Sensing Range M12 x 1.5 hijyenik (A02) / G 1/2 A hijyenik (A03) / BHC 3 / A DN 38 (B01) / ISO 2852 (Tri-Clamp), DN 25; 33.7; 38, Ø 50.5 (C04) / Varivent® DN 32 … 125; 1 1/2" … 6" (Type N), Ø 68 (V02)
Baumer Temperature measurement

PT55H

Temperature sensor

Technical Specifications

Housing Sensor lengthsee "Ordering information" sectionOther lengths ≤ 3000 mm on request
Sensing Range
  • M12 x 1.5 hijyenik (A02) / G 1/2 A hijyenik (A03) / BHC 3 / A DN 38 (B01) / ISO 2852 (Tri-Clamp), DN 25
  • 33.7
  • 38, Ø 50.5 (C04) / Varivent® DN 32 … 125
  • 1 1/2" … 6" (Type N), Ø 68 (V02)
Features
  • Precision measurement from -50 to 250 °C
  • Integrated 4 to 20 mA transmitter for high accuracy
  • Touchscreen in a compact housing
  • Convenient installation and easy operation
  • IO-Link Dual Channel for easy commissioning
  • In addition to the standard lengths, custom lengths of up to 3000 mm are available on request

Detailed Technical Data

Output signal

Interface IO-Link 1.1FlexProgrammer 9701 with
Damping 0 … 60 s , programmable
Accuracy ± 0.05 % FSR
Current rating 100 mA , max..
Load resistance Rs ≤ (V DC - 15 V)/23 mA, 2 wire modRs ≤ (V DC - 10 V)/23 mA, 3 and 4 wire mode
Off leakage current < 160 μA , max..
Output type PNPNPNDijital (push-pull)
Ripple immunity < 1 % FSR (1 Vrms, 50Hz...1kHz)
Voltage düşüşü < 2 V, switching output
Switching mantığı High Active, Low Active
Basamak response time, T90 < 25 ms
Supply voltage dalgalanmasının etkisi < 0.01 % FSR/V (± 1.6 µA/V), deviating from 24 VDC

Environmental Conditions

Humidity ≤ 100 % RH , condensing
Protection degree (EN 60529) IP67IP69K , suitable matching connector with
Vibration (sinüzoidal) (EN 60068-2-6) 1.6 mm p-p (2 … 25 Hz), 4 g (25 … 100 Hz), 1 octave / dk.

Process connection

Sensor length "Order bilgisi" bölümüne bakın3000 mm'ye up to other uzunluklar on request
Sensor tube material AISI 316L (1.4404)
Wet part surface pürüzlülüğü Ra ≤ 0.8 µmRa ≤ 0.8 µm, electropolished, optionalRa ≤ 0.4 µm, optionalRa ≤ 0.4 µm, electropolished, optional

COMPLIANCE AND APPROVALS

EMC EN 61326-1EN 61326-2-3Deviation during immunity testing ≤ 0.2% FSR
Hygiene 3-A (74-07)EHEDG EL Class I

Performance Features

Process temperature "Operating conditions" see section
Max.. measurement error ± 0.06 % FSR @ 25 °CSıfır point and range error, non-linearity (terminal base to the line according to), hysteresis and non-repeatability includes (EN 61298-2)
Temperature coefficient < 0.025 K/KFactor of change in ambient temperature from 25°C
Power-on time < 1500 ms @ 24 V
Termal response time, T50 RTD element and verici combined< 2.5 s , Ø4 mm< 6.5 s , Ø6 mm< 10.5 s , Ø8 mm
Temperature drift (by ambient) < 0.1 % FSR/K (± 1.6 µA/K)Faktör of change in ortam temperature itibaren 25°C
Pt100 accuracy class (EN 60751) 1/1 B ± (0.3 + 0.005 × t)°C1/1 A ± (0,15 + 0,002 × t)°C1/3 B ± 1/3 × (0.3 + 0.005 × t)°C1/6 B ± 1/6 × (0.3 + 0.005 × t)°C

Documents

architecture CAD open_in_new Open
shopping_cart

Quote Cart

shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3
Canlı sohbet çok yakında aktif edilecektir.