Housing
Sensor lengthsee "Ordering information" sectionOther lengths ≤ 3000 mm on request
Sensing Range
Threadless / G 1/2 A ISO 228-1 (G06) / G 1/2 A hygienic (A03) / M12 x 1.5 hygienic (A02) / M12 × 1.5 hygienic, PEEK cone, sensor tip Ø 3x5 mm (A02) / G1/8 ISO 228/1 female thread, Hygienic (A01) / G 1/4 A DIN EN ISO 1179-2 (3852-E) (G50) / ISO 2852 (Tri-Clamp), DN 25; 33.7; 38, Ø 50.5 (C04) / Tri-Clamp DN 3/4" Ø 24.9 (C01) / BHC 3 / A DN 38 (B01) / 1/2-14 NPT (N02) / 1/4-18 NPT (N01) / G 1/2 A DIN EN ISO 1179-2 (3852-E) (G51)
Baumer
Temperature measurement
TE2
Temperature sensor
Technical Specifications
Housing
Sensor lengthsee "Ordering information" sectionOther lengths ≤ 3000 mm on request
Sensing Range
- Threadless / G 1/2 A ISO 228-1 (G06) / G 1/2 A hygienic (A03) / M12 x 1.5 hygienic (A02) / M12 × 1.5 hygienic, PEEK cone, sensor tip Ø 3x5 mm (A02) / G1/8 ISO 228/1 female thread, Hygienic (A01) / G 1/4 A DIN EN ISO 1179-2 (3852-E) (G50) / ISO 2852 (Tri-Clamp), DN 25
- 33.7
- 38, Ø 50.5 (C04) / Tri-Clamp DN 3/4" Ø 24.9 (C01) / BHC 3 / A DN 38 (B01) / 1/2-14 NPT (N02) / 1/4-18 NPT (N01) / G 1/2 A DIN EN ISO 1179-2 (3852-E) (G51)
Features
- Compact and robust design
- Precision measurement from -50 to 250 °C
- Integrated 4 to 20 mA transmitter or Pt100 output
- Easy process integration from DN 25 or in-tank
- In addition to the standard lengths, custom lengths of up to 3000 mm are available on request
Detailed Technical Data
Output signal
Vericili
4 … 20 mA , 2 wire
Vericisiz
1 x Pt100, 4 wire
Environmental Conditions
Humidity
≤ 100 % RH , condensing
İzolasyon direnci
> 100 MΩ , 500 V DC (Rail versiyonu for)
İzolasyon voltage
600 V AC , EN 50155 (Rail versiyonu for)
Protection degree (EN 60529)
IP 65 , with DIN EN 175301-803 A (DIN 43650 A), 4-pinIP 68 , M12-A, 4 pin and suitable cable with
Long-term test (transmitter)
IEC 770 6.3.2
Vibration (sinüzoidal) (EN 60068-2-6)
1.6 mm p-p (2 … 25 Hz), 4 g (25 … 100 Hz), 1 octave / dk.
Process connection
Sensor length
"Order bilgisi" bölümüne bakın3000 mm'ye up to other uzunluklar on request
Sensor tube material
AISI 316L (1.4404)
Wet part surface pürüzlülüğü
Ra ≤ 0.8 µm
COMPLIANCE AND APPROVALS
EMC
EN 61000-6-2EN 61000-6-3EN 61326-1NE21
Hygiene
FDA (21 CFR 177.2415)3-A (74-07)
Explosion protection
Ex ia Basit device, gaz and dust
Railway applications
EN 50155
Performance Features
Process pressure
"Operating conditions" see section
Process temperature
"Operating conditions" see section
Termal response time, T50
RTD element only ≤ 1.0 s, conical sensor ≤ 1.3 s, Ø3 mm ≤ 2.5 s, Ø4 mm ≤ 3.0 s, Ø6 mm
Termal response time, T90
RTD element only≤ 3.0 s , Ø3 mm≤ 3.6 s , Ø4 mm≤ 8.5 s , Ø6 mm
Pt100 accuracy class (EN 60751)
1/1 B ± (0.3 + 0.005 × t)°C1/1 A ± (0,15 + 0,002 × t)°C1/3 B ± 1/3 × (0.3 + 0.005 × t)°C1/6 B ± 1/6 × (0.3 + 0.005 × t)°C