Sensing Range
G 1/2 A hijyenik (A03)
Baumer
Temperature measurement
TER8
Temperature sensor
Technical Specifications
Sensing Range
G 1/2 A hijyenik (A03)
Features
- Optimum placement even in agitators and pigging systems
- Integrated 4 … 20 mA transmitter or Pt100 output
- Very fast response time
- Elastomers that do not comply with 3-A standards
Detailed Technical Data
Output signal
Vericili
4 … 20 mA , 2 wire
Vericisiz
1 x Pt100, 4 wire
Şönt direnci
Rs ≤ (Vs - 8 V)/0.023 ARs ≤ 680 Ohm, Vs = 24 V DC
Environmental Conditions
Humidity
< 98 % RH , condensing
Protection degree (EN 60529)
IP67IP69K , suitable cable with
Vibration (sinüzoidal) (EN 60068-2-6)
1.6 mm p-p (2 … 25 Hz), 4 g (25 … 100 Hz), 1 octave / dk.
Process connection
Daldırma length
0 mm , front-flush20 mm50 mm
Wetted parts material
PEEK Natura
Sensor tube material
AISI 316L (1.4404)
Wet part surface pürüzlülüğü
Ra ≤ 0.8 µm
COMPLIANCE AND APPROVALS
EMC
EN 61000-6-2EN 61000-6-3EN 61326-1
Hygiene
FDA (21 CFR 177.2415)3-A (74-07)
Performance Features
Sampling interval
0.5 s
Min. output span
25 °C
Process temperature
115 … 135 °C , < 1 h-40 … 115 °C , permanent
Max.. output error
± 0.1 % FSR± 0.016 mA
Max.. dönüşüm error
± 0.25 °C
Termal response time, T50
≤ 2.5 s , 20 mm.≤ 2.7 s , 50 mm≤ 9.0 s , front-flush
Termal response time, T90
≤ 6.5 s , 20 mm≤ 6.7 s , 50 mm≤ 66.0 s , front-flush
Temperature drift (by ambient)
< 0.003 % FSR/°C , typical< 0.01 % FSR/°C , max..
Pt100 accuracy class (EN 60751)
1/1 B ± (0.3 + 0.005 × t)°C1/1 A ± (0,15 + 0,002 × t)°C1/3 B ± 1/3 × (0.3 + 0.005 × t)°C1/6 B ± 1/6 × (0.3 + 0.005 × t)°C