TER8
Sensing Range G 1/2 A hijyenik (A03)
Baumer Temperature measurement

TER8

Temperature sensor

Technical Specifications

Sensing Range G 1/2 A hijyenik (A03)
Features
  • Optimum placement even in agitators and pigging systems
  • Integrated 4 … 20 mA transmitter or Pt100 output
  • Very fast response time
  • Elastomers that do not comply with 3-A standards

Detailed Technical Data

Output signal

Vericili 4 … 20 mA , 2 wire
Vericisiz 1 x Pt100, 4 wire
Şönt direnci Rs ≤ (Vs - 8 V)/0.023 ARs ≤ 680 Ohm, Vs = 24 V DC

Environmental Conditions

Humidity < 98 % RH , condensing
Protection degree (EN 60529) IP67IP69K , suitable cable with
Vibration (sinüzoidal) (EN 60068-2-6) 1.6 mm p-p (2 … 25 Hz), 4 g (25 … 100 Hz), 1 octave / dk.

Process connection

Daldırma length 0 mm , front-flush20 mm50 mm
Wetted parts material PEEK Natura
Sensor tube material AISI 316L (1.4404)
Wet part surface pürüzlülüğü Ra ≤ 0.8 µm

COMPLIANCE AND APPROVALS

EMC EN 61000-6-2EN 61000-6-3EN 61326-1
Hygiene FDA (21 CFR 177.2415)3-A (74-07)

Performance Features

Sampling interval 0.5 s
Min. output span 25 °C
Process temperature 115 … 135 °C , < 1 h-40 … 115 °C , permanent
Max.. output error ± 0.1 % FSR± 0.016 mA
Max.. dönüşüm error ± 0.25 °C
Termal response time, T50 ≤ 2.5 s , 20 mm.≤ 2.7 s , 50 mm≤ 9.0 s , front-flush
Termal response time, T90 ≤ 6.5 s , 20 mm≤ 6.7 s , 50 mm≤ 66.0 s , front-flush
Temperature drift (by ambient) < 0.003 % FSR/°C , typical< 0.01 % FSR/°C , max..
Pt100 accuracy class (EN 60751) 1/1 B ± (0.3 + 0.005 × t)°C1/1 A ± (0,15 + 0,002 × t)°C1/3 B ± 1/3 × (0.3 + 0.005 × t)°C1/6 B ± 1/6 × (0.3 + 0.005 × t)°C

Documents

description Datasheet open_in_new Open
menu_book User Manual open_in_new Open
verified Certificates open_in_new Open
architecture CAD open_in_new Open
shopping_cart

Quote Cart

shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3
Canlı sohbet çok yakında aktif edilecektir.