Housing
Blind hollow shaft
Sensing Range
3601 … 5000
Baumer
Heavy duty combinations
HOG 86 + FSL
Technical Specifications
Housing
Blind hollow shaft
Sensing Range
3601 … 5000
Features
HTL-P (power line driver)TTL/RS422
Detailed Technical Data
TEKNIK VERILER - MEKANIK TASARIM
Resistance
IEC 60068-2-6 Vibration 5 g, 10-2000 HzIEC 60068-2-27 Shock 50 g, 11 ms
Material
Body: aluminum, coated; Shaft: stainless steel
Speed (n)
≤1.25 · ns
Connection
2x terminal box3x terminal box (with option M)
Shaft type
ø16 mm (blind recessed mil)ø17 mm (conical shaft 1:10)
Dimension (flange)
ø105 mm
Protection EN 60529
IP 66
Corrosion protection
IEC 60068-2-52 Tuz sisiISO 12944-2 per spec C4 ambient conditions for
Approximate weight
1.9 kg2 kg (with option M)
Rotor moment of inertia
200 gcm²
Operating temperature
-40...+100 °C-25...+100 °C (>3072 pulses)
Operating torque (typical)
6 Ncm
İzin verilen shaft load
≤350 N axial≤450 N radial
Switching speed range (ns)
850...4500 rpm (Δn = 2 rpm/s)
TECHNICAL DATA - ELECTRICAL RATINGS
Approval
CE
Emitted interference
EN 61000-6-3
Interference immunity
EN 61000-6-2
Technical Data - Electrical Values (Encoder)
Phase shift
90 ° ±20°
Shaft isolation
Suitable up to 2.8 kV
Reference signal
Zero pulse, width 90°
Supply voltage
9...30 VDC5 VDC ±5 %
Output stages
HTL-P (heavy-duty line driver)TTL/RS422
Duty cycle
45…55 %40…60 % (>3072 pulses)
Output frequency
≤120 kHz≤300 kHz (upon request)
Output signals
K1, K2, K0 + invertedError output (EMS option)
İletim length
≤350 m at 100 kHz (HTL-P)≤550 m at 100 kHz (TTL)
Detection method
Optical
Pulses per revolution
500 … 5000
Consumption w/o load
≤100 mA
Technical Data - Electrical Values (Centrifugal Switch)
Switching sapması
≤3 % (cw-ccw rotation)
Switching accuracy
± 4 % (Δn = 2 rpm/s),20 % (Δn = 1500 rpm/s)
Switching hysteresis
40 % of switching speed
Switching outputs
1 output, speed control
Minimum switching current
50 mA
Output switching capacity
≤6 A / 230 VAC≤1 A / 125 VDC(EAC: <50 VAC / 75 VDC)