OM 502I
Orbitmerret Panel ölçüm cihazları Ölçüm cihazları

OM 502I

Technical Specifications

Input Signal Proses (4-20mA) / Pals
Display / Digits 5 hane
Mounting Panel montaj (96×48 mm)
Output / Communication Röle + RS-485

Detailed Technical Data

tune Input
* – Number of inputs
1 input
LX – Range
selectable from menu
0…5 mA
< 300 mV
input I
0…20 mA
< 300 mV
input I
4…20 mA
< 300 mV
input I
±2 V
1,8 MOhm
input U
±5 V
1,8 MOhm
input U
±10 V
1,8 MOhm
input U
LX – Linearisation
through the OM Link program
through 256 noktalı lineer interpolasyon and 16 tablo
tune Display
Display range
-99999…999999, single-colour 14-segment LED
Display height
14 mm
Display colour
red, green
Description
son iki hane ekranın ölçülen değişkenleri göstermek for kullanılabilir
Decimal point
adjustable from menu - fixed
Display brightness
adjustable from menu
tune Settings
Control
the device is controlled and set using the five buttons on the front panel
Menu
LIGHT | contains only the items required for basic device settings, accessed with a password
PROFI | All device settings, accessed with a password
USER | user menu made up of any items selected from LIGHT/PROFI. Access without password.
OM Link
The OM Link program is also designed for visualising and logging measured values from multiple devices
tune Device Accuracy and Functions
Temperature coefficient
50 ppm/°C
Accuracy
±0,02 % of range + 1 digit
Speed
1…100 measurement/s
Overload capacity
2x
10x (t < 30 ms)
Linearisation
50 noktalı lineer interpolasyon (only OM Link via)
Digital filters
arithmetic average | 2…100 measurements
floating average | 2…30 measurement
exponential average | 2…100 measurement
Functions
Tare | resets the display on a non-zero input signal
Min/max. value | measurement sırasında ulaşılan min./max. value kaydeder
Tepe value | display only max. or min. değerleri gösterir
Mat. functions
polynomial, 1/x, logarithm, exponential, power, root, sin x
Data kaydı
RTC | period - 1 s…1 gün, zaman-tarih-display value, < 266k data, 15 ppm/°C
FAST | 40 records/s, display value, < 8k data
Monitoring function
400 ms
Calibration
at 25°C and 40% relative humidity
tune Data Outputs
Protocol
MODBUS - RTU, PROFIBUS DP
RS 232
isolated
RS 485
isolated, max. adresleme: 31 device
tune Sensor supply
Adjustable
5…24 VDC/max. 1,2 W
tune Power supply
Power supply
10…30 V AC/DC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
80…250 V AC/DC, ±10%, PF > 0.4, I < 40 A/1 ms, isolated
tune Operating Conditions
Connection
terminal connection card, cable cross-section < 1,5/2,5 mm²
Operating temperature
-20°…60°C
Storage temperature
-20°…85°C
Protection class
IP64 (only front panel)
Electrical safety
EN 61010-1, A2
EMC
EN 61326-1
tune Mechanical Characteristics
Material
Noryl GFN2 SE1, flame-retardant UL 94 V-I
Dimensions
96 x 48 x 120 mm (w x h x d)

Documents

description
Veri Sayfaları Veri Sayfası OM502 (v2015.1)
download Download
description
Veri Sayfaları Veri Sayfası OM502I (v2023.1)
download Download
description
Kullanıcı Kılavuzları Kullanım Talimatları OMProfi (v2020.3)
download Download
description
Kullanıcı Kılavuzları Kullanım Talimatları OMProfibus (v2014.2.1)
download Download
description
Kullanıcı Kılavuzları Kullanım Talimatları OM502 (v2022.4.1)
download Download
description
Uygulama Notları Uygulama Notu Handling RealTime memory (v2006.01)
download Download
description
Uygulama Notları Uygulama Notu Firmware upload (v2006.02)
download Download
description
Uygulama Notları Uygulama Notu Modbus commands OM 502I (v2019)
download Download
description
Uygulama Notları Uygulama Notu MODBUS data protocol (v2020.01)
download Download
description
Uygulama Notları Uygulama Notu Protocol MODBUS description (v2006.01)
download Download
description
Sertifikalar Sertifika EU_Declaration_OM502 (v2022)
download Download
description
Sertifikalar Sertifika Declaration_17050_OM502 (v2022)
download Download
description
Yazılım (Firmware) OM 502I 78-605 (v2019)
download Download
description
Yazılım GSD OM-Profibus (v2020)
download Download
description
Yazılım GSDML OM-Profinet (v2024.2.33)
download Download
description
CAD OM Krabicka (v2014)
download Download
shopping_cart

Quote Cart

shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3
Canlı sohbet çok yakında aktif edilecektir.