Orbitmerret
Panel ölçüm cihazları; Nükleer santral cihazları
Ölçüm cihazları; Ölçüm cihazları (Nükleer)
OM 602AV
Technical Specifications
Input Signal
Analog giriş / RS komutu
Display / Digits
6 hane
Mounting
Panel montaj (96×48 mm)
Output / Communication
Analog çıkış (mA/V)
Detailed Technical Data
tune
Input
AV – Type
isolated, programmable with a 16bit D/A transducer
output type and range are selectable in menu
AV – Range
0…2 V
0…5 V
0…10 V
±10 V
0…5 mA
compensation < 1 000 Ohm/24 V
0…20 mA
compensation < 1 000 Ohm/24 V
4…20 mA
compensation < 1 000 Ohm/24 V
AV – Non-linearity
0,1 % of range
AV – Temperature coefficient
15 ppm/°C
AV – Speed
value değişimine yanıt < 1 ms
AV – Functions
RUCNE | manual setting of output value
SINUS | sinus output signal
PILA | saw output signal
OBDEL. | rectangular output signal
NAHOD. | random generated signal
External inputs – Number
3 input, contact input
External inputs – Functions
OFF | No function
HOLD | stops the measurement (option
Display - Analog output - Limits)
BLOK.K. | locks the front panel keys
B.HESL. | blocks access to the LIGHT/PROFI menu
NUL. M.M. | resets the min./max. value
K1 NAH. | Gross step - Up
K1 DOL. | Gross step - Down
K2 NAH. | Fine step - Up
K2 DOL. | Fine step - Down
MIN. H. | Minimum range
MAX. H. | Maximum range
ZVYSUJ | Increases output every 10 ms one "Step"
SNIZUJ | Decreases output every 10 ms one "Step"
START | Starting preset cycle
STOP | Stopping preset cycle
ST.-ST. | Start/Stop of the preset cycle
tune
Display
Display range
-99999…999999, single-colour 14-segment LED
-999…9999, 3-colour 7-segment LED
Display height
14 mm, 20 mm
Display colour
red, green, red/green/orange
Signal LED'i
1, 2, 3, 4 | Limits L1, L2, L3, L4 (red)
Description
son iki hane ekranın ölçülen değişkenleri göstermek for kullanılabilir (only 14 mm'lik display)
Decimal point
adjustable from menu - fixed or floating
Display brightness
adjustable from menu
Displayed values
Kan A | channel A value
Fil. A | channel A value, after digital filtering
Mat. Fn. | Matematiksel function value
tune
Settings
Control
the device is controlled and set using the five buttons on the front panel
The selected functions can also be controlled via the external inputs
Menu
LIGHT | contains only the items required for basic device settings, accessed with a password
PROFI | All device settings, accessed with a password
USER | user menu made up of any items selected from LIGHT/PROFI. Access without password.
İsteğe bağlı functions
ZAKAZ | düğmenin function none
MENU | Selected menu öğesine doğrudan erişim
MANUAL | Manual setting
START | Starting set cycle
STOP | Stopping set cycle
ST.-ST. | Start/Stopof the set cycle
OM Link
the company's communication interface for running, configuring and updating the device firmware
The OM Link program is also designed for visualising and logging measured values from multiple devices
tune
Device Accuracy and Functions
Temperature coefficient
50 ppm/°C
Mat. functions
polynomial, 1/x, logarithm, exponential, power, root, sin x
Monitoring function
400 ms
Calibration
at 25°C and 40% relative humidity
tune
Comparators
Type
Digital, adjustable from menu, contact bağlantısı < 30 ms
Mode
Hysteresis | sets the switching point, hysteresis band "Mez ± 1/2 Hys." and time (0 ... 99.9 s) switching delay
From-To | ON and OFF output range
Dose | period, multiples and time (0 ... 99.9 s), duration the output is active
Output
1x relay, change contact (250 VAC/30 VDC, 3 A)
2x relay, change contact (250 VAC/30 VDC, 3 A)
1x relay, kapama contact (250 VAC/30 VDC, 3A)
2x relay, kapama contact (250 VAC/30 VDC, 3 A)
2x bistabil relay (250 VAC/30 VDC, 3A)
3x relay, 2x açılış + 1x change contact (250 VAC/30 VDC, 3A)
4x relay, 2x açılış + 2x change contact (250 VAC/30 VDC, 3A)
2x open collector (30 VDC/100 mA)
4x open collector (30 VDC/100 mA)
2x açık kolektör (30 VDC/100 mA) + 2x relay, CO contact (250 VAC/30 VDC, 3 A)
2x SSR (250 VAC/1 A)
tune
Data Outputs
Protocol
ASCII, MESSBUS, MODBUS - RTU, PROFIBUS DP
Data formatı
8 bit + parite none + 1 stop bit (ASCII)
7 bit + double parity + 1 stop bit (Messbus)
Speed
600…230 400 Baud
0,0096…12 MBaud (PROFIBUS)
RS 232
isolated
RS 485
isolated, max. adresleme: 31 device
tune
Sensor supply
Adjustable
5…24 VDC/max. 1,2 W
tune
Power supply
Power supply
10…30 V AC/DC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
80…250 V AC/DC, ±10%, PF > 0.4, I < 40 A/1 ms, isolated
Current consumption
< 9,4 W/9,2 VA
Power supply protection
protected by a fuse inside the device
tune
Operating Conditions
Connection
terminal connection card, cable cross-section < 1,5/2,5 mm²
Stabilisation time
within 15 minutes after power-on
Operating temperature
-20°…60°C
Storage temperature
-20°…80°C
Protection class
IP64 (only front panel)
Electrical safety
EN 61010-1, A2
Dielectric strength
4 kVAC for 1 min. between power supply and input
4 kVAC 1 min. for power supply with data/analog output between
4 kVAC for 1 min. between input and relay output
2,5 kVAC 1 min. for input with data/analog output between
Insulation resistance
power supply | 670 V (ZI), 300 V (Di)*
input, output, PN | 300 V (ZI), 150 V (Di)*
EMC
EN 61326-1
Seismic capacity
IEC 980: 1993, pair.6
Software verification
Compliance: IEC 62138, 61226, class B, C
tune
Mechanical Characteristics
Material
Noryl GFN2 SE1, flame-retardant UL 94 V-I
Dimensions
96 x 48 x 120 mm (w x h x d)
Panel cut-out dimensions
90,5 x 45 mm (w x h)