OM 602UQC
Orbitmerret Panel ölçüm cihazları Ölçüm cihazları

OM 602UQC

Technical Specifications

Input Signal Frekans / Sayıcı
Display / Digits 6 hane
Mounting Panel montaj (96×48 mm)
Output / Communication RS-232 / RS-485

Detailed Technical Data

tune Input
UQC – Input
2 independent inputs, selectable from menu
on contact, TTL, NPN/PNP, Line
0...60 V, comparison levels are adjustable in the menu
UQC – Input frequency
0,002 Hz…1 MHz
0,002 Hz…100 kHz (mode STRIDA)
0,002 Hz…500 kHz (mod QUADR and UP/DW)
UQC – Measurement mode
SINGLE | Counter/frequency
A + B | Counter/frequency with AND function
xNOR | Counter/frequency with NOR function
STRIDA | Duty cycle measurement
QUADR | Counter/frekans for IRC sensor
UP/DW | Counter/frequency
UP - DW | Counter/frequency
TIME | Stopwatch
RTC | Clock
UQC – Time base
0,05/1/2/3/5/10/20 s
1/2/5/10 min
UQC – Calibration coefficient
0,00001…999999
UQC – Front setting
0…999999
UQC – Input filtresi
out
1/10/100/250/500/1 000 kHz
1/10/45/55/65/100 Hz
2/5/10 s
1/10 min
UQC – Functions
Preset | initial non-zero value, which is always read after resetting the instrument
current value | single setting of the initial value
Summation | registration of numbers during shift operation
Time backup | time is running even when the device is off (the display is off either)
External inputs – Number
3 input, contact input
External inputs – Functions
OFF | No function
HOLD | stops the measurement (option
Display - Analog output - Limits)
BLOK.K. | locks the front panel keys
B.HESL. | blocks access to the LIGHT/PROFI menu
TARA x | Dara activation - channel 1, 2, All, current
Suma x | Toplam gösterimi - channel 1, 2
N.SUM. x | Resetting sum - channel 1, 2, both
NUL. T.x | Darayı sıfırla - 1, 2, All, current
NUL. M.M. | resets the min./max. value
ULOZ | data logging activation (option
RTC/FAST)
PREP. | Kademeli or BCD channel change
tune Display
Display range
-99999…999999, single-colour 14-segment LED
Display height
14 mm
Display colour
red, green
Signal LED'i
T | Tare (green)
M | Min./Max. value (yeşil)
C, F, 1, 2 | channellar 1, 2 - counter, frekans (turuncu)
Description
son iki hane ekranın ölçülen değişkenleri göstermek for kullanılabilir (only 14 mm'lik display)
Decimal point
adjustable from menu - fixed or floating
Display brightness
adjustable from menu
Displayed values
Kan C1 | Value from channel 1 - Counter
Fil. C1 | Value from channel 1 - Counter after digital filtering
Kan F1 | Value from channel 1 - frekans
Fil. F1 | Value from channel 1 - frekans after digital filtering
Kan C2 | Value from channel 2 - Counter
Fil. C2 | Value from channel 2 - Counter after digital filtering
Fil. F2 | Value from channel 2 - frekans after digital filtering
Kan F2 | Value from channel 2 - frekans
Mat. Fn. | Matematiksel function value
Max. | Maksimum value
Min. | Minimum value
tune Settings
Control
the device is controlled and set using the five buttons on the front panel
The selected functions can also be controlled via the external inputs
Menu
LIGHT | contains only the items required for basic device settings, accessed with a password
PROFI | All device settings, accessed with a password
USER | user menu made up of any items selected from LIGHT/PROFI. Access without password.
İsteğe bağlı functions
ZAKAZ | düğmenin function none
NUL. C.x. | Counter reset - channel 1, 2, both
N. SUM.x. | Summation reset - channel 1, 2, both
NUL. M.M. | Min/Max. değerleri sıfırla
NUL. T.x | Darayı sıfırla - channel 1, 2, both, current
MENU | Selected menu öğesine doğrudan erişim
DOC. H. | temporary display of the selected values
PREP. 1 | channel change on display
ULOZ | Ölçülen verinin device belleğine kaydedilmeye başlanması
NUL. PA. | Measurement verisi belleğini sıfırla
START | Start for Stopwatch/watch
PAUZA | Until the next touch the display will show the last value
CLR | Resetting Stopwatch/Watch
STOP | Stopping Stopwatch/Watch
OM Link
the company's communication interface for running, configuring and updating the device firmware
The OM Link program is also designed for visualising and logging measured values from multiple devices
tune Device Accuracy and Functions
Temperature coefficient
50 ppm/°C
Accuracy
±0,01 % of range + 1 digit (frekans)
Overload capacity
2x
10x (t < 30 ms)
Linearisation
50 noktalı lineer interpolasyon (only OM Link via)
Digital filters
arithmetic average | 2…100 measurements
floating average | 2…30 measurement
exponential average | 2…100 measurement
rounding | sets the display step
input filter | transmits input signal range 1 MHz...10 min
Functions
Tare | resets the display on a non-zero input signal
Min/max. value | measurement sırasında ulaşılan min./max. value kaydeder
Tepe value | display only max. or min. değerleri gösterir
Preset | initial non-zero value, which is read after each counter reset
Summation | number registration upon shift operation
Time backup | time is running even when the power is off (display is off either)
current value | single setting of the initial value
Mat. functions
polynomial, 1/x, logarithm, exponential, power, root, sin x
Math. operations between inputs
sum and division
Data kaydı
RTC | period - 1 s…1 gün, zaman-tarih-display value, < 266k data, 15 ppm/°C
FAST | 40 records/s, display value, < 8k data
Time yedekleme
Lithium cell CR 2032RV, 3V/220 mAh
Monitoring function
400 ms
Calibration
at 25°C and 40% relative humidity
tune Comparators
Type
Digital, adjustable from menu, contact bağlantısı < 30 ms
Mode
Hysteresis | sets the switching point, hysteresis band "Mez ± 1/2 Hys." and time (0 ... 99.9 s) switching delay
From-To | ON and OFF output range
Dose | period, multiples and time (0 ... 99.9 s), duration the output is active
C-Pulse | auto counter reset on the preset value
On Run | output is active while stopwatch is running
Output
1x relay, change contact (250 VAC/30 VDC, 3 A)
2x relay, change contact (250 VAC/30 VDC, 3 A)
1x relay, kapama contact (250 VAC/30 VDC, 3A)
2x relay, kapama contact (250 VAC/30 VDC, 3 A)
2x bistabil relay (250 VAC/30 VDC, 3A)
3x relay, 2x açılış + 1x change contact (250 VAC/30 VDC, 3A)
4x relay, 2x açılış + 2x change contact (250 VAC/30 VDC, 3A)
2x open collector (30 VDC/100 mA)
4x open collector (30 VDC/100 mA)
2x açık kolektör (30 VDC/100 mA) + 2x relay, CO contact (250 VAC/30 VDC, 3 A)
2x SSR (250 VAC/1 A)
tune Data Outputs
Protocol
ASCII, MESSBUS, MODBUS - RTU, PROFIBUS DP
Data formatı
8 bit + parite none + 1 stop bit (ASCII)
7 bit + double parity + 1 stop bit (Messbus)
Speed
600…230 400 Baud
0,0096…12 MBaud (PROFIBUS)
RS 232
isolated
RS 485
isolated, max. adresleme: 31 device
tune Analog Outputs
Type
İzoleli, programlanabilir, 16-bit D / A converter, type and range selectable from menu
Temperature coefficient
15 ppm/°C
Non-linearity
±0,1 % of range
Speed
value değişimine yanıt < 1 ms
Ranges
0...2 V, 0...5 V, 0...10 V, ±10 V, 0...5 mA, 0...20 mA, 4...20 mA
Compensation
600 Ohm/12 V, 1 000 Ohm/24 V
Error status
of rangeda 4...20mA
error message indicator (<3.0 mA)
current döngüsü kesintisi tespiti
tune Sensor supply
Adjustable
5…24 VDC/max. 1,2 W
tune Power supply
Power supply
10…30 V AC/DC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
80…250 V AC/DC, ±10%, PF > 0.4, I < 40 A/1 ms, isolated
Current consumption
< 8,0 W/7,8 VA
Power supply protection
protected by a fuse inside the device
tune Operating Conditions
Connection
terminal connection card, cable cross-section < 1,5/2,5 mm²
Stabilisation time
within 15 minutes after power-on
Operating temperature
-20°…60°C
Storage temperature
-20°…80°C
Protection class
IP64 (only front panel)
Electrical safety
EN 61010-1, A2
Dielectric strength
4 kVAC for 1 min. between power supply and input
4 kVAC 1 min. for power supply with data/analog output between
4 kVAC for 1 min. between input and relay output
2,5 kVAC 1 min. for input with data/analog output between
Insulation resistance
power supply | 670 V (ZI), 300 V (Di)*
input, output, PN | 300 V (ZI), 150 V (Di)*
EMC
EN 61326-1
Seismic capacity
IEC 980: 1993, pair.6
tune Mechanical Characteristics
Material
Noryl GFN2 SE1, flame-retardant UL 94 V-I
Dimensions
96 x 48 x 120 mm (w x h x d)
Panel cut-out dimensions
90,5 x 45 mm (w x h)

Documents

description
Veri Sayfaları Veri Sayfası OM602UQC (v2023.1)
download Download
description
Kullanıcı Kılavuzları Kullanım Talimatları OMProfi (v2020.3)
download Download
description
Kullanıcı Kılavuzları Kullanım Talimatları OMProfibus (v2014.2.1)
download Download
description
Kullanıcı Kılavuzları Kullanım Talimatları OM602UQC (v2010.1.1)
download Download
description
Uygulama Notları Uygulama Notu Handling RealTime memory (v2006.01)
download Download
description
Uygulama Notları Uygulama Notu Firmware upload (v2006.02)
download Download
description
Uygulama Notları Uygulama Notu Modbus commands OM 602UQC (v2018)
download Download
description
Uygulama Notları Uygulama Notu Protocol MODBUS description (v2006.01)
download Download
description
Sertifikalar Sertifika EU_Declaration_OM602 (v2022)
download Download
description
Sertifikalar Sertifika Declaration_17050_OM602 (v2022)
download Download
description
Sertifikalar Sertifika Seismic_test_OM602UQC (v2007)
download Download
description
Yazılım (Firmware) OM 602UQC 78-601 (v2018)
download Download
description
Yazılım GSD OM-Profibus (v2020)
download Download
description
Yazılım GSDML OM-Profinet (v2024.2.33)
download Download
description
CAD OM Krabicka (v2014)
download Download
shopping_cart

Quote Cart

shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3
Canlı sohbet çok yakında aktif edilecektir.