OMM 323UQC
Technical Specifications
Input Signal
Frekans / Sayıcı
Display / Digits
4 hane
Mounting
Panel montaj (48×24 mm)
Output / Communication
—
Detailed Technical Data
tune
Input
* – Number of inputs
1 input
UQC – Input
on contact, TTL, NPN/PNP
0...30 V, comparison levels are adjustable from menu or automatic
UQC – Input frequency
0,1 Hz…50 kHz (mode SINGLE)
0,1 Hz…20 kHz (mode UP/DW)
0,1 Hz…20 kHz (UP-DW)
0,1 Hz…20 kHz (mode QUADR. - frequency)
0,1 Hz…10 kHz (mode QUADR. - counter)
(for 50% duty cycle)
UQC – Measurement mode
SINGLE | Counter/frequency
QUADR | Counter/frekans for IRC sensor
UP/DW | Counter/frequency
UP - DW | Counter/frequency
TIME | Stopwatch
UQC – Time base
0,5/1/2/5/10 s
UQC – Calibration coefficient
0,001…9999
UQC – Front setting
0…9999
UQC – Input filtresi
out
5/40/100/1 000 Hz
UQC – Functions
Preset | initial non-zero value, which is always read after resetting the instrument
current value | single setting of the initial value
Summation | registration of numbers during shift operation
External inputs – Number
1 input, contact input
External inputs – Functions
OFF | No function
HOLD | stops the measurement (option
Display - Analog output - Limits)
LOCK | Front panel tuşlarını kilitle
TARE | Dara activation
CLEAR | display reset
SUM | Total display
CL.SUM. | Resetting sum
NUL. TA. | resets the tare
CLR. ST. | input clears (presets) stop-watch/counter, Stop-watch also stops
COUNT. | Switching display Counter/frequency
tune
Display
Display range
-999…9999, single-colour 7-segment LED
Display height
9,1 mm
Display colour
red, green
Decimal point
adjustable from menu - fixed or floating
Display brightness
adjustable from menu, automatically
Displayed values
COUNT. | Value from channel Counter
FREQ. | Value from channel frequency
tune
Settings
Control
The device is controlled and set by dört buttons located under the front panel
The selected functions can also be controlled via the external inputs
Menu
LIGHT | contains only the items required for basic device settings, accessed with a password
PROFI | All device settings, accessed with a password
USER | user menu made up of any items selected from LIGHT/PROFI. Access without password.
OM Link
the company's communication interface for running, configuring and updating the device firmware
The OM Link program is also designed for visualising and logging measured values from multiple devices
tune
Device Accuracy and Functions
Temperature coefficient
50 ppm/°C
Accuracy
±0,05 % of range + 1 digit
±0,02 % of value ±2 ms (stopwatch)
Overload capacity
2x
10x (t < 30 ms)
Linearisation
25 noktalı lineer interpolasyon (only OM Link via)
Digital filters
exponential average | 2…100 measurements
rounding | sets the display step
input filter | transmits input signal range 5…1 000 Hz
1/Fr. | filter for frequency conversion to time
Functions
Tare | resets the display on a non-zero input signal
Preset | initial non-zero value, which is read after each counter reset
Summation | number registration upon shift operation
current value | single setting of the initial value
Monitoring function
500 ms
Calibration
at 25°C and 40% relative humidity
tune
Power supply
Power supply
10…30 VDC/24 VAC, ±10 %, PF > 0,4, I < 45 A/1 ms, isolated
Current consumption
< 1,0 W/1,1 VA
tune
Operating Conditions
Connection
terminal connection card, cable cross-section < 1,5 mm²
Stabilisation time
within 15 minutes after power-on
Operating temperature
-20°…60°C
Storage temperature
-20°…80°C
Protection class
IP42 (only front panel)
Electrical safety
EN 61010-1, A2
Dielectric strength
2,5 kVAC for 1 min. between power supply and input
Insulation resistance
power supply | 300 V (ZI)*
EMC
EN 61326-1
tune
Mechanical Characteristics
Material
Noryl GFN2 SE1, flame-retardant UL 94 V-I
Dimensions
48 x 24 x 72 mm (w x h x d)
Panel cut-out dimensions
43,5 x 21,5 mm (w x h)