OMM 650UC
Orbitmerret Panel ölçüm cihazları Ölçüm cihazları

OMM 650UC

Technical Specifications

Input Signal Universal (çoklu giriş)
Display / Digits 6 hane
Mounting Panel montaj (72×24 mm)
Output / Communication Röle

Detailed Technical Data

tune Input
UQC – Input
selectable from menu
on contact, TTL, NPN/PNP
0...30/300 V, comparison levels are adjustable from menu or automatic
UQC – Input frequency
0,1 Hz…50 kHz (mode SINGLE)
0,1 Hz…20 kHz (mode UP/DW)
UQC – Measurement mode
SINGLE | Counter/frequency
UP/DW | Counter/frequency
TIME | Stopwatch
RTC | Clock
UQC – Time base
0,5/1/2/5/10 s
UQC – Calibration coefficient
0,00001…999999
UQC – Front setting
0…999999
UQC – Input filtresi
out
5/40/100/1 000 Hz
UQC – Functions
Preset | initial non-zero value, which is always read after resetting the instrument
Time backup | time is running even when the device is off (the display is off either)
External inputs – Number
1 input, contact input
External inputs – Functions
OFF | No function
HOLD | stops the measurement (option
Display - Analog output - Limits)
LOCK | Front panel tuşlarını kilitle
TARA | tare activation
CLEAR | display reset
CLR. ST. | input clears (presets) stop-watch/counter, Stop-watch also stops
tune Display
Display range
-99999…999999,single-colour 7-segment LED
Display height
9,1 mm
Display colour
red, green
Signal LED'i
1, 2 | Limits L1, L2 (red)
T | Tare (green)
Decimal point
adjustable from menu - fixed or floating
Display brightness
adjustable from menu
tune Settings
Control
Device front paneldeki dört düğme with control edilir and ayarlanır
Menu
LIGHT | contains only the items required for basic device settings, accessed with a password
PROFI | All device settings, accessed with a password
USER | user menu made up of any items selected from LIGHT/PROFI. Access without password.
İsteğe bağlı functions
ZAKAZ | düğmenin function none
TARE | Dara function activation
NUL. TA. | resets the tare
START | Start for Stopwatch/watch
CLR | Resetting Stopwatch/Watch
STOP | Stopping Stopwatch/Watch
OM Link
the company's communication interface for running, configuring and updating the device firmware
The OM Link program is also designed for visualising and logging measured values from multiple devices
tune Device Accuracy and Functions
Temperature coefficient
50 ppm/°C
Accuracy
±0,05 % of range + 1 digit
±0,02 % of value ±2 ms (stopwatch)
±0,02 % of value ±130 ms (RTC)
Overload capacity
2x
10x (t < 30 ms) - for değil 300 V
Linearisation
25 noktalı lineer interpolasyon (only OM Link via)
Digital filters
exponential average | 2…100 measurements
rounding | sets the display step
input filter | transmits input signal range 5…1 000 Hz
Functions
Tare | resets the display on a non-zero input signal
Preset | initial non-zero value, which is read after each counter reset
Time backup | time is running even when the power is off (display is off either)
Time yedekleme
Lithium cell CR 2032RV, 3V/220 mAh
Monitoring function
500 ms
Calibration
at 25°C and 40% relative humidity
tune Comparators
Type
Digital, adjustable from menu, contact bağlantısı < 50 ms
Mode
Hysteresis | sets the switching point, hysteresis band "Mez ± 1/2 Hys." and time (0 ... 99.9 s) switching delay
C-Pulse (L1) | auto counter reset on the preset value
On Run (L2) | output is active while stopwatch is running
Output
1x bistabil relay (48 VAC/30 VDC, 3A)
2x bistabil relay (48 VAC/30 VDC, 3A)
1x open collector (30 VDC/100 mA)
2x open collector (30 VDC/100 mA)
tune Power supply
Power supply
10…30 VDC/24 VAC, ±10 %, PF > 0,4, I < 45 A/1 ms, isolated
Current consumption
< 2,1 W/2,2 VA
tune Operating Conditions
Connection
terminal connection card, cable cross-section < 1,5 mm²
Stabilisation time
within 15 minutes after power-on
Operating temperature
-20°…60°C
Storage temperature
-20°…80°C
Protection class
IP42 (only front panel)
Electrical safety
EN 61010-1, A2
Dielectric strength
2,5 kVAC for 1 min. between power supply and input
4 kVAC for 1 min. between input and relay output
Insulation resistance
power supply | 300 V (ZI)*
input, output | 300 V (ZI), 150 V (Di)*
EMC
EN 61326-1
Seismic capacity
IEC 980: 1993, pair.6
tune Mechanical Characteristics
Material
Noryl GFN2 SE1, flame-retardant UL 94 V-I
Dimensions
72 x 24 x 106 mm (w x h x d)
Panel cut-out dimensions
68 x 21,5 mm (w x h)

Documents

description
Veri Sayfaları Veri Sayfası OMM650UC (v2023.1)
download Download
description
Veri Sayfaları Veri Sayfası OMM350_650 (v2008.1)
download Download
description
Kullanıcı Kılavuzları Kullanım Talimatları OMM650UC (v2007.1.3)
download Download
description
Sertifikalar Sertifika EU_Declaration_OMM350 (v2016)
download Download
description
Sertifikalar Sertifika Declaration_17050_OMM350_650 (v2022)
download Download
description
Yazılım (Firmware) OMM650UC 61-013 OM UC (v2008)
download Download
shopping_cart

Quote Cart

shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3
Canlı sohbet çok yakında aktif edilecektir.