Technical Specifications
Input Signal
Proses (4-20mA)
Mounting
DIN ray
Output / Communication
Analog çıkış (mA/V)
Detailed Technical Data
tune
Input
* – Number of inputs
1 input
PM – Range
±2 V
1 MOhm
input 1
±5 V
1 MOhm
input 1
±10 V
1 MOhm
input 1
0…5 mA
< 200 mV
input I
0…20 mA
< 200 mV
input I
4…20 mA
< 200 mV
input I
tune
Display
Signal LED'i
PWR, SET | Device status signaling (RGB)
tune
Settings
Control
The device is controlled and set by a single button on the front panel
OM Link
the company's communication interface for running, configuring and updating the device firmware (microUSB)
The OM Link program is also designed for visualising and logging measured values from multiple devices
tune
Device Accuracy and Functions
Temperature coefficient
15 ppm/°C
Accuracy
±0,1 % of range (for 20 measurements/s)
Speed
1…100 measurement/s
Overload capacity
2x
10x (t < 30 ms)
Linearisation
lineární interpolací v 100 bodech (pouze přes OM Link)
Digital filters
arithmetic average | 2…100 measurements
floating average | 2…30 measurement
exponential average | 2…100 measurement
zaokrouhlení | nastavení pevného kroku pro změnu hodnoty
Functions
Tare | resets the display on a non-zero input signal
Teach-in | semiautomatic regime of input calibration
Simulation | simulation input signal/function of the device
Mat. functions
polynomial, invertní polynomial, logarithm, exponential, power, root
Monitoring function
500 ms
Calibration
at 25°C and 40% relative humidity
tune
Analog Outputs
Output sayısı
1 output
Type
İzoleli, programlanabilir with resolution of max.10,000 steps, type and range selectable from menu
Temperature coefficient
15 ppm/°C
Non-linearity
±0,1 % of range
Ranges
0…10 V / 10...0 V (resistive load > 2.6 kOhm), 0...20 mA, 4…20 mA / 20...4 mA (aktivní/pasivní)
Compensation
600 Ohm/12 V
Error status
error message indicator (<3.0 mA)
tune
Sensor supply
Fixed
24 VDC/35 mA, isolate (only for 4...20mA)
tune
Power supply
Power supply
10…30 VDC/24 VAC, ±10 %, PF > 0,4, I < 40 A/1 ms, isolated
Current consumption
< 2,4 W/2,6 VA
Power supply protection
protected by a fuse inside the device
tune
Operating Conditions
Connection
terminal connection card, cable cross-section < 2,5 mm²
Stabilisation duration
within 5 minutes after power-on
Operating temperature
-20°…60°C
Storage temperature
-20°…85°C
Protection class
IP20
Electrical safety
EN 61010-1, A2
Dielectric strength
2,5 kVAC for 1 min. between power supply and input
2,5 kVAC for 1 min. between input and output
Insulation resistance
supply of the device | 300 V (ZI), 255 V (DI)
input, output | 300 V (ZI)*
EMC
EN61326-1: 2006
Seismic capacity
IEC/IEEE 60980-344 ed. 1.0:2020, pair 6,9
Mechanical dayanıklılık
[Mechanical Characteristics]
Material
PA 66, flame-retardant UL 94 V-0 (black)
Dimensions
114,5 x 99 x 12,5 mm (w x h x d)
Installation
DIN rail, width 35 mm