Orbitmerret
Sinyal dönüştürücüler
Dijital dönüştürücüler
OMX 390LVDT
Technical Specifications
Input Signal
LVDT sensörü
Mounting
DIN ray
Output / Communication
Analog çıkış (mA/V)
Detailed Technical Data
tune
Input
LVDT – Range
1/3/5 VAC with frequency of 2.5/5/10 kHz
LVDT – Cable bağlantısı
3, 4, 5 nebo 6drátové
tune
Settings
Control
Přístroj is ovládá a nastavuje dvěna tlačítky na předním panelu a DIP přepínačem na boku krabičky
İsteğe bağlı functions
TARE | Dara function activation
NUL. TA. | resets the tare
Teach-in | setting the analog input range
OM Link
the company's communication interface for running, configuring and updating the device firmware (microUSB)
The OM Link program is also designed for visualising and logging measured values from multiple devices
tune
Device Accuracy and Functions
Temperature coefficient
15 ppm/°C
Accuracy
±0,1 % of range
Speed
1…100 measurement/s
Overload capacity
2x
10x (t < 30 ms)
Linearisation
lineární interpolací v 100 bodech (pouze přes OM Link)
Digital filters
arithmetic average | 2…100 measurements
floating average | 2…30 measurement
exponential average | 2…100 measurement
rounding | sets the display step
Functions
Tare | resets the display on a non-zero input signal
Offset | compensation of the difference between measured a actual/required value
Min/max. value | measurement sırasında ulaşılan min./max. value kaydeder
Teach-in | semiautomatic regime of input calibration
Simulation | simulation input signal/function of the device
Delayed start | time when is not performed measurement after connection of the device k supply
Mat. functions
polynomial, invertní polynomial, 1/x, logarithm, exponential, power, root
Monitoring function
500 ms
Calibration
at 25°C and 40% relative humidity
tune
Data Outputs
Output sayısı
1 output
Type
RS 485, isolated
10/100BaseT, Modbus TCP/IP (Slave)
Protocol
MODBUS - RTU, MODBUS - TCP/IP
Data formatı
Format | 8bit + parity + stop bit
Parity | none / even / odd
Stop bit | 1 / 1.5 / 2
Speed
600…230 400 Baud
100 Mbit/s
RS 485
isolated, max. adresleme: 31 device
Address
MODBUS | < 246 instruments
Line termination
by dahili resistor 120 Ohm
tune
Analog Outputs
Output sayısı
1 output
Type
İzoleli, programlanabilir, 16-bit D / A converter, type and range selectable from menu
Temperature coefficient
15 ppm/°C
Accuracy
±0,02 % full scale
±0,03 % full scale (0…5 V)
±0,05 % full scale (0…2 V / 0…5 mA)
Speed
value değişimine yanıt < 160 µs
Ranges
0…2 / 5 / 10 V, ±10 V, resistive load > 1 k?
0…5 / 20 mA / 4…20 mA, comp. < 600 Ohm / V
Error status
error message indicator (<3.0 mA)
tune
Power supply
Power supply
10…30 VDC/24 VAC, ±10 %, PF > 0,4, I < 45 A/1 ms, isolated
Current consumption
< 3,5 W/3,9 VA
Power supply protection
protected by a fuse inside the device
tune
Operating Conditions
Connection
terminal connection card, cable cross-section < 1,5 mm²
Stabilisation duration
within 5 minutes after power-on
Operating temperature
-20°…60°C
Storage temperature
-20°…85°C
Operation humidity
< 95 % relative nem, yoğuşmayan
Protection class
IP20
Electrical safety
EN 61010-1, A2
Dielectric strength
2,5 kVAC for 1 min. between power supply and input
2,5 kVAC for 1 min. between input and output
Insulation resistance
supply of the device | 300 V (ZI), 255 V (DI)
input, output | 300 V (ZI)*
EMC
EN 61326-1
RoHS
IEC 63000 : 2018
Seismic capacity
IEC/IEEE 60980-344 ed. 1.0:2020, pair 6,9
Mechanical dayanıklılık
EN 60068-2-6 ed. 2:2008
tune
Mechanical Characteristics
Material
PA 66, flame-retardant UL 94 V-0 (black)
Dimensions
25 x 79 x 90 mm (w x h x d)
Installation
DIN rail, width 35 mm
Documents
description
Kullanıcı Kılavuzları
Kullanım Talimatları OMX390LVDT_ETH (v2024.1.02)
download
Download