Order No
101144078
Article Code
101144078
Certificates
cULus
Schmersal
Emniyetli Anahtarlama ve Denetleme
Ayrı Aktüatörlü Emniyet Şalterleri
AZ 17-02ZI-ST B1
Product Description
- • IP Rating: IP67 | Weight: 86 g | Certification: cULus | PL d
Standards
- • EN ISO 13849-1
Product Features
- • Connector M12 x 1, 4-pole_x000D_
- • Termoplastik gövde_x000D_
- • Çift yalıtımlı_x000D_
- • Uzun ömürlü_x000D_
- • 30 mm x 60 mm x 30 mm_x000D_
- • Particularly suitable for sliding doors_x000D_
- • Kompakt gövde_x000D_
- • Bireysel kodlama_x000D_
- • ISO 14119'a göre yüksek kodlama seviyesi_x000D_
- • Düşük gerilim ve akımlarda yüksek kontak güvenilirliği_x000D_
- • Kirlenmeye karşı duyarsız_x000D_
- • Slot sealing plug included_x000D_
- • 8 actuating planes
Technical Specifications
Note
2 channel usage and suitable logic birim with.
Mounting
Vidalar
Category
3
General Note
IDC method esnek of the conductors connection provides. Hinge axis 10 mm above must be. Rotary guard system minimum 140 mm. Hinged in guards minimum 200 mm.
Mission Time
20 Year(s)
Please Note
Single channel mekanizmaya tehlikeli hasar for fault of excluding kabul edilebilir that it is and to manipulation counter sufficient protection garanti that is done cases...
Gross Weight
86 g
Housing Material
Plastik, cam elyaf takviyeli termoplastik, automatically fading
Contact Material
Silver
Locking Force
5 N
Pollution Degree
3
Sensor Length
30 mm
Scope of Delivery
Socket cover for dust-proof closure of the unused opening
IP Protection Class
IP67
Ambient Temperature
-30 ... +80 °C
Performance Level
d
Sensor Width
30 mm
Thermal Test Current
0.4166666666678793
Operating Principle
Mekanik
Actuator Material
Stainless steel
Switching Element
2 NK contact
Switching Principle
Slow hareket, pozitif opening NK contact
Mechanical Life (min.)
1,000,000 Cycles
Sensor Height
85 mm
Number of Cable Glands
1
B10D NC Contact Value
2,000,000 Cycles
Positive Opening Distance
11 mm
Fixing Screw Type
2x M4
Terminal Connection
M12 connector plug, 4 pole (A coded)
Max. Actuation Speed
2 m/s
Max. Installation Altitude
2,000 m
Number of Safety Contacts
2
Number of Actuation Directions
2
Current Utilization Cat. AC-15
0.16666666666787933
Current Utilization Cat. DC-13
0.16666666666787933
Min. Positive Opening Force
34 N
Note (Switching Element)
Galvanik separated contact bridges
Overvoltage Category
III
Max. Switching Frequency
2,000 /h
Voltage Utilization Cat. AC-15
230 VAC
Voltage Utilization Cat. DC-13
24 VDC
Impulse Withstand Voltage (Uimp)
4 kV
Storage/Transport Temperature
-30 ... +85 °C
Coding Level (EN ISO 14119)
High
Min. Positive Opening Force/Contact
17 N
Rated Insulation Voltage (Uᵢ)
250 VAC
Required Rated Short-Circuit Current
1,000 A