AZ201-I2-SK-T-1P2P
Order No 103015818
Article Code 103015818
Certificates TÜV cULus FCC IC ANATEL UKCA
Schmersal Emniyetli Anahtarlama ve Denetleme Ayrı Aktüatörlü Emniyet Şalterleri

AZ201-I2-SK-T-1P2P

Product Description

  • IP Rating: IP66/IP67 | Voltage: 24 VDC | Weight: 403 g | PL e

Standards

  • EN ISO 13849-1 EN IEC 61508

Product Features

  • Repeated individual coding with RFID technology_x000D_
  • ISO 14119'a göre yüksek kodlama seviyesi_x000D_
  • Termoplastik gövde_x000D_
  • İhtiyaca dayalı müdahale koruması için RFID teknolojisi_x000D_
  • Sensör zincirinin maks. uzunluğu 200 m_x000D_
  • Kendinden izlemeli seri kablolama_x000D_
  • Çalışma koşullarını gösteren 3 LED_x000D_
  • Sensor technology permits an offset between actuator and interlock of ± 5 mm vertically and ± 3 mm horizontally_x000D_
  • Menteşeli ve kızaklı koruyucular için uygun_x000D_
  • Akıllı diagnostik

Technical Specifications

Note All belirtimler iletken end included.
Coding Individual coding, multiple teaching
Category 4
PFD Value 1.60 x 10⁻⁴
PFH Value 1.90 x 10⁻⁹ /h
Impact Resistance 30 g / 11 ms
Mission Time 20 Year(s)
Max. Hysteresis 1.5 mm
Min. Wire Cross-Section 23 AWG
Series Connection Yes
Gross Weight 403 g
Housing Material Cam elyaf takviyeli termoplastik
Protection Class III
Max. Wire Cross-Section 15 AWG
Locking Force 30 N
Pollution Degree 3
Max. Relative Humidity 0.93
Min. Cable Cross-Section 0.25 mm²
Note (Relative Humidity) Non-condensing, non-icing
Sensor Length 50 mm
Scope of Delivery Actuator additionally order must be.
Vibration Resistance 10 … 150 Hz, amplitude 0.35 mm
Max. Cable Cross-Section 1.5 mm²
Max. Risk Time 200 ms
Operating Current 50 mA
24V Current Consumption 5 mA
IP Protection Class IP66 IP67
Short-Circuit Detection Yes
Ambient Temperature -25 ... +70 °C
Performance Level e
Sensor Width 40 mm
Operating Voltage 24 VDC -15% / +10% (stabilized PELV power source)
Operating Principle RFID, 125 kHz
Mechanical Life (min.) 1,000,000 Cycles
Sensor Height 220 mm
Recommendation (Actuator) AZ/AZM201-B1 AZ/AZM201-B30
Repeat Accuracy R 0.5 mm
Switching Thresholds −3 V … 5 V (Low) 15 V … 30 V (High)
Note (Series Connection) Unlimited number of devices; observe the external line fuse; max. 31 devices when using serial diagnostics (SD)
Cross-Circuit Detection Yes
Fixing Screw Type 2x M6
Terminal Connection Threaded terminal block M20 x 1,5
Max. Actuation Speed 0.2 m/s
Max. Leakage Current (Ir) 0.5 mA
Suitable SIL Applications 3
Safety Functions Yes
Max. Installation Altitude 2,000 m
Max. Test Pulse Duration 0.5 ms
Permissible Cable Type Single core solid / very core solid / esnek
Number of Safety Contacts 2
Max. Ready Time 4,000 ms
Current Utilization Cat. DC-13 0.05 A
Min. Test Pulse Interval 100 ms
Note (Switching Distance) All switching distances EN IEC 60947-5-3'e is according to
Overvoltage Category III
Rated Operating Voltage 24 VDC
Typical Test Pulse Interval 1000 ms
Voltage Utilization Cat. DC-13 24 VDC
Guaranteed Opening Distance (ON) Sao 4 mm
Safety Inputs Definition X1 and X2
Max. Voltage Drop (Ud) 4 V
Max. Transmitter RFID Output -6 dBm
Impulse Withstand Voltage (Uimp) 0.8 kV
Guaranteed Opening Distance (OFF) Sar 30 mm
Control Elements Design Short devre resistant, p-type
Storage/Transport Temperature -25 ... +85 °C
Integrated System Diagnostics Status Yes
Coding Level (EN ISO 14119) High
Max. Sensor Chain Length 200 m
Note (Sensor Chain Length) Cable length and cross-section change the voltage drop depending on the output current
Safety Outputs Definition Y1 and Y2
Rated Insulation Voltage (Uᵢ) 32 VDC
Diagnostic Outputs Definition OUT
Max. Switching Frequency (Approx.) 1 Hz
Housing Cover Screw Torque (Min.) 0.7 Nm
Required Rated Short-Circuit Current 100 A
External Wire and Device Fuse Rating 4A gG
Housing Cover Screw Torque (Max.) 1 Nm
ZVEI CB24I Sink Classification C1 C2
ZVEI CB24I Source Classification C2
Typical Idle Operating Current (I₀) 50 mA
Note (LED Switching Condition Indication) Operating status: LED green / Fault / functional failure: LED red / Supply voltage UB: LED green
Rated Operating Current (Safety Outputs) 250 mA
Max. Response Time (Actuator to Safety Output Off) 100 ms
Max. Response Time (Safety Input to Safety Output Off) 0.5 ms