AZM300Z-I2-ST-AS
Order No 103005920
Article Code 103005920
Certificates TÜV cULus ASi-SaW ECOLAB ANATEL
Schmersal Emniyetli Anahtarlama ve Denetleme Solenoid Kilitler

AZM300Z-I2-ST-AS

Product Description

  • IP Rating: IP66/IP67/IP69 | Voltage: 26.5 ... 31.6 VDC | Weight: 605 g | PL e

Standards

  • EN ISO 13849-1 EN IEC 61508

Product Features

  • Termoplastik gövde_x000D_
  • Repeated individual coding with RFID technology_x000D_
  • ISO 14119'a göre yüksek kodlama seviyesi_x000D_
  • Menteşeli ve kızaklı koruyucular için uygun_x000D_
  • 3 different directions of actuation_x000D_
  • Kapı kilitleme izleniyor_x000D_
  • Açmak için güç gerekli_x000D_
  • Magnet supply through the AS-Interface_x000D_
  • Hijyenik tasarım_x000D_
  • Protection class IP 69_x000D_
  • Solenoid interlock with integrated AS-i Safety Interface_x000D_
  • Universal repeatedly teachable or individual coding because of the RFID technology_x000D_
  • I-variants with coding level HIGH to ISO 14119_x000D_
  • 2 integrated snap-in stages

Technical Specifications

PIN 1 AS-Interface +
PIN 2 Aux - (P)
PIN 3 AS-Interface -
PIN 4 Aux + (P)
Coding Individual coding, multiple teaching
Category 4
General Note For doors flush with the door frame, the optional MP-AZ/AZM300-1 mounting plate can be used. For glass and Makrolon doors, the optional MS-AZ/AZM300-B1-1 mounting kit can be used.
PFD Value 2.34 x 10⁻⁴
PFH Value 1.34 x 10⁻⁹ /h
AS-i Profile S-7.B.F.E
Impact Resistance 30 g / 11 ms
Latching Yes
AS-i Version V 3.0
Mission Time 20 Year(s)
Gross Weight 605 g
Housing Material Cam elyaf takviyeli termoplastik
Protection Class III
Pollution Degree 3
Max. Relative Humidity 0.93
Note (Relative Humidity) Non-condensing, non-icing
Sensor Length 120 mm
Scope of Delivery Actuator additionally order must be.
Vibration Resistance 10 … 150 Hz, amplitude 0.35 mm
Force to Open Yes
Max. Risk Time 200 ms
Manual Lock Release Yes
AS-i Specification Safety Slave
AS-i Output DO 0 Solenoid control
AS-i Output DO 1 No function
AS-i Output DO 2 No function
AS-i Output DO 3 No function
IP Protection Class IP66 IP67 IP69
Max. Response Time 120 ms
Ambient Temperature +0 ... +60 °C
Performance Level e
RFID Frequency Band 125 kHz
Sensor Width 87.5 mm
Operating Principle RFID
Mechanical Life (min.) 1,000,000 Cycles
Note (Mechanical Life) When used as a door stop: ≥ 50,000 cycles (door mass ≤ 5 kg and actuation speed ≤ 0.5 m/s)
Sensor Height 35 mm
Recommendation (Actuator) AZ/AZM300-B1
AS-i Input Channel 1 Veri bitleri DI 0 / DI 1 = dinamik kod iletimi
AS-i Input Channel 2 Veri bitleri DI 2 / DI 3 = dinamik kod iletimi
Fixing Screw Type 2x M6
Terminal Connection M12 connector plug, 4 pole (A coded)
Suitable SIL Applications 3
Safety Functions Yes
Max. Installation Altitude 2,000 m
Max. Holding Force Fmax 1,500 N
Solenoid Lock Monitored Yes
AS-i Parameter Bits P0 Guard door closed and can be locked
AS-i Parameter Bits P1 Solenoid interlock locked
AS-i Parameter Bits P2 Auxiliary voltage in
AS-i Parameter Bits P3 Internal device error (FID)
Max. Ready Time 5,000 ms
AS-i Max. Current Consumption 200 mA
Number of Actuation Directions 3
Note (Switching Distance) All switching distances EN IEC 60947-5-3'e is according to
Typical Switching Distance 2 mm
AS-i Input Module Address 0
Overvoltage Category III
Magnet Release Time 1
Rated Operating Voltage 26.5 ... 31.6 VDC (Reverse polarity protection)
Min. Fixing Screw Torque 6 Nm
Note (AS-i Parameter Bits) Set the parameter outputs to "1111" (0xF). FID: peripheral error
Guaranteed Opening Distance (ON) Sao 1 mm
Max. Fixing Screw Torque 7 Nm
Max. Transmitter RFID Output -6 dBm
Impulse Withstand Voltage (Uimp) 0.8 kV
Guaranteed Opening Distance (OFF) Sar 20 mm
Storage/Transport Temperature -10 ... +90 °C
Integrated System Diagnostics Status Yes
Locking Force Adjustment Position 1 25 N
Locking Force Adjustment Position 2 50 N
Coding Level (EN ISO 14119) High
Holding Force FZh (EN ISO 14119) 1,150 N
Rated Insulation Voltage (Uᵢ) 32 VDC
Note (AS-i Input Module Address) Adres 0'a front set; AS-interface bus master or el type programlama device with changeable
Note (LED Switching Condition Indication) (1) green/red LED (AS-i duo LED): Supply voltage/communication error/slave address=0/peripheral unit error/device error/tamper protection active (2) Yellow LED: Device status (Enable status) (3) Red LED: Internal...
Max. Solenoid Lock-Actuator Angular Misalignment 2 °