Order No
103002178
Article Code
103002178
Certificates
ATEX (Konformitätserklärung)
Schmersal
Emniyetli Anahtarlama ve Denetleme
Emniyet Sensörleri
EX-BNS 40S-12ZG-C 5,0M
Product Description
- • IP Rating: IP65/IP67 | Weight: 409 g | Cable: 5 m | Contacts: 2 NC, 1 NO
Standards
- • EN ISO 13849-1
Product Features
- • ATEX Zon 2 ve 22 için patlama koruması_x000D_
- • Stainless steel enclosure_x000D_
- • 88 mm x 27 mm x 14,5 mm_x000D_
- • Gizli montaj mümkün_x000D_
- • Yanal hizasızlığa karşı duyarsız_x000D_
- • Mekanik aşınma yok_x000D_
- • Suitable for food processing industry_x000D_
- • Cable connection suitable for the food industry
Technical Specifications
Coding
Yes
General Note
Contact sembolleri, guard of the device closed condition for is shown. LED'li or LED'siz of the versions contact configuration is the same.
Active Area
Yanal
Cable Type
LiYY
Wire Cross-Section
23 AWG
Impact Resistance
30 g / 11 ms
Mission Time
20 Year(s)
Direction of Movement
Active to the surface vertical
Cable Length
5 m
Gross Weight
409 g
Housing Material
Stainless steel (V4A)
Manufacturer Declaration
ATEX Zone 2 and 22
Sensor Length
14.5 mm
Scope of Delivery
Actuator additionally order must be.
Vibration Resistance
10 … 55 Hz, amplitude 1 mm
Number of Cable Wires
6
Actuation Element
Magnet
IP Protection Class
IP65 IP67
Short-Circuit Detection
Yes
Ambient Temperature
-20 ... +60 °C
Sensor Width
88 mm
Switching Element
1 NA contact, 2 NK contact
Switching Principle
Reed contacts, non-contact prensip
Max. Impact Energy
7 J
Housing Design Form
Blok
Sensor Height
27 mm
Recommendation (Actuator)
BPS 40S-2 BPS 40S-1-C BPS 40S-2-C
Cross-Circuit Detection
Yes
Terminal Connection
Cable
Explosion Protection Definition
D II 3G Ex nA nC IIC T6 Gc D II 3D Ex tc IIIC T80°C Dc X
Connection Diagram Note
S21-S22 contact safety devresine integrated must be.
B10D NC/NA Contact Value
25,000,000 Cycles
Cable Sheath Material
PVC
Max. Switching Current
0.01 A
Explosion Protection Zones
2 22
Explosion Protection Category
3G 3D
Max. Switching Voltage
24 VDC
Mechanical Mounting Conditions
Embedded not
Note (Switching Distance)
All switching distances EN IEC 60947-5-3'e is according to
Hidden Threaded Holes at the Rear
Yes
Max. Switching Capacity
0.24 W
Guaranteed Opening Distance (ON) Sao
8 mm
Guaranteed Opening Distance (OFF) Sar
18 mm
Explosion Protection Regulations
EN IEC 60079-0 EN IEC 60079-15 EN 60079-31
Storage/Transport Temperature
-25 ... +80 °C
Recommended Safety Switch
SRB-E-301ST SRB-E-201LC
Integrated System Diagnostics (General)
Yes
Precondition Evaluation Unit
Yes
Max. Switching Frequency (Approx.)
5 Hz
Required Rated Short-Circuit Current
100 A
Number of NO (Normally Open) Contacts
1
Number of NC (Normally Closed) Contacts
2
Note (Integrated System Diagnostics Status)
LED, guard when closed yanar.