Order No
131165063
Article Code
131165063
Certificates
CCC
Schmersal
Emniyetli Anahtarlama ve Denetleme
Solenoid Kilitler
TZMW4Ö24VDC
Product Description
- • IP Rating: IP65/IP67 | Weight: 480 g | Certification: CCC | PL d
Standards
- • EN ISO 13849-1
Product Features
- • Termoplastik gövde_x000D_
- • Holding force 1500 N
Technical Specifications
Note
All belirtimler iletken end included.
Mounting
Vidalar
Category
3
General Note
Locks operating on the lock-to-lock principle may only be used in special cases, after a thorough assessment of accident risk, since interruption of the electrical supply or the main switch...
Application Note
Slide-mounted guard cover removable cover hinged guard cover
Mission Time
20 Year(s)
Please Note
Single channel mekanizmaya tehlikeli hasar for fault of excluding kabul edilebilir that it is and to manipulation counter sufficient protection garanti that is done cases...
Gross Weight
480 g
Housing Material
Cam elyaf takviyeli termoplastik
Contact Material
Silver
Locking Force
20 N
Min. Cable Cross-Section
1 x 0.5 mm²
Note (Relative Humidity)
Non-condensing, non-icing
Sensor Length
41 mm
Scope of Delivery
TZ/CO actuator teslimata included.
Max. Cable Cross-Section
1 x 1.5 mm²
IP Protection Class
IP65 IP67
Ambient Temperature
+0 ... +50 °C
Performance Level
d
Sensor Width
129 mm
Thermal Test Current
0.16666666666787933
Operating Principle
Elektromekanik
Switching Principle
Slow hareket
Mechanical Life (min.)
1,000,000 Cycles
Sensor Height
92.5 mm
B10D NA Contact Value
1,000,000 Cycles
B10D NC Contact Value
2,000,000 Cycles
Force to Lock
Yes
Positive Opening Distance
3.5 mm
Fixing Screw Type
3x M6
Terminal Connection
Threaded terminal block
Max. Actuation Speed
0.3 m/s
Max. Test Pulse Duration
5 ms
Rated Control Voltage
24 VDC
Number of Safety Contacts
4
Number of Actuation Directions
4
Current Utilization Cat. AC-15
0.16666666666787933
Current Utilization Cat. DC-13
0.16666666666787933
Min. Positive Opening Force
20 N
Min. Test Pulse Interval
50 ms
Number of Auxiliary Contacts
0
Max. Switching Frequency
1,200 /h
Magnet Release Time
1
Voltage Utilization Cat. AC-15
230 VAC
Voltage Utilization Cat. DC-13
24 VDC
Impulse Withstand Voltage (Uimp)
2.5 kV
Coding Level (EN ISO 14119)
Low
Holding Force FZh (EN ISO 14119)
1,500 N
Max. Electrical Power Consumption
8.5 W
Min. Positive Opening Force/Contact
20 N
Rated Insulation Voltage (Uᵢ)
250 VAC
Housing Cover Screw Torque (Min.)
0.8 Nm
Required Rated Short-Circuit Current
1,000 A
Housing Cover Screw Torque (Max.)
0.8 Nm