Order No
101128797
Article Code
101128797
Certificates
cULus
Schmersal
Emniyetli Sinyal İşleme
Güvenlik Rölesi ve Kontrol Modülleri
AES 1102.3 24 VAC
Product Description
- • Voltage: 24 VAC | Dimensions: 22.5mm×75mm×110mm | Weight: 124 g | Certification: cULus | Contacts: 4 NC, 2 NO | PL c
Standards
- • EN ISO 13849-1 EN IEC 61508
Product Features
- • BNS serisi manyetik güvenlik sensörü izleme_x000D_
- • 1 güvenlik kontağı, STOP 0
Technical Specifications
Mounting
Fits onto a standard DIN rail per EN 60715
Warning
maks. 50.000 switching cycle/year and maks. %80 contact load for
Depth
110 mm
Category
1
General Note
Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width
22.5 mm
Height
75 mm
PFH Value
1.14 x 10⁻⁶ /h
Number of LEDs
1
Impact Resistance
30 g / 11 ms
EMC Class
EMC Directive
Application Note
Safety sensor Guard system
Mission Time
20 Year(s)
Gross Weight
124 g
Housing Material
Glass-fibre reinforced thermoplastic, ventilated
Contact Material
AgCdO
Pollution Degree
2
Vibration Resistance
10...55 Hz, Amplitude 0.35 mm, ± 15 %
Frequency Range
50 Hz 60 Hz
Clip Tightening Torque
0.6 Nm
Max. Cable Cross-Section
2.5 mm²
Terminal (Mechanical)
Threaded terminal block
Climatic Resistance
EN 60068-2-3 BG-GS-ET-14
Stop Category
0
Ambient Temperature
+0 ... +55 °C
Performance Level
c
Thermal Test Current
0.16666666666787933
IP Protection (Housing)
IP40
Max. Contact Resistance
0.1 Ω
Mechanical Life (min.)
3,000,000 Cycles
Note (Contact Resistance)
In new condition
Terminal Definitions
IEC/EN 60947-1
Reset When Power is Removed
Yes
Max. Transmission Resistance
40 Ω
Wire Breakage Detection
Yes
Suitable SIL Applications
1
Connection Diagram Note
Monitoring of multiple protective doors using BNS magnetic safety sensors, to safeguard one or more protective doors up to PL c and Category 1. The connection diagram is shown with the protective doors closed and de-energized.
Permissible Cable Type
Single core solid / esnek
Number of Safety Contacts
1
IP Protection (Mounting Area)
IP54
Automatic Reset Function
Yes
Current Utilization Cat. AC-15
1.5 A
Current Utilization Cat. DC-12
0.1 A
Current Utilization Cat. DC-13
0.041666666667879326
Overvoltage Category
III
Electrical Power Consumption
2.4 W
Min. Switching Capacity
10 mA
Rated Operating Voltage
24 VAC
AC Control Voltage 50Hz min.
20.4 VAC
AC Control Voltage 60Hz min.
20.4 VAC
Voltage Utilization Cat. AC-15
250 VAC
Voltage Utilization Cat. DC-12
24 VDC
Voltage Utilization Cat. DC-13
24 VDC
IP Protection (Terminal Block)
IP20
Max. Switching Capacity
0.08333333333212067
AC Control Voltage 50Hz max.
26.4 VAC
AC Control Voltage 60Hz max.
26.4 VAC
Impulse Withstand Voltage (Uimp)
4 kV
Emergency Release Delay
20 ms
Storage/Transport Temperature
-25 ... +70 °C
Integrated System Diagnostics Status
Yes
Pull-In Delay After RESET
20 ms
Displayed Operating States
Yetkili operation
Number of NO (Normally Open) Contacts
2
Release Delay on Power Failure
80 ms
Number of NC (Normally Closed) Contacts
4
Pull-In Delay on Automatic Start
100 ms