AZM300Z-I1-ST-AS-P-T
Order No 103009480
Article Code 103009480
Certificates TÜV cULus ASi-SaW ECOLAB ANATEL
Schmersal Emniyetli Anahtarlama ve Denetleme Solenoid Kilitler

AZM300Z-I1-ST-AS-P-T

Product Description

  • IP Rating: IP66/IP67/IP69 | Voltage: 24 VDC | Weight: 646 g | PL e

Standards

  • EN ISO 13849-1 EN IEC 61508

Product Features

  • Termoplastik gövde_x000D_
  • Individual coding with RFID technology_x000D_
  • ISO 14119'a göre yüksek kodlama seviyesi_x000D_
  • Menteşeli ve kızaklı koruyucular için uygun_x000D_
  • 3 different directions of actuation_x000D_
  • Kapı kilitleme izleniyor_x000D_
  • Açmak için güç gerekli_x000D_
  • Emergency exit_x000D_
  • Solenoid supply 24 VDC (Aux)_x000D_
  • Hijyenik tasarım_x000D_
  • Protection class IP 69_x000D_
  • Solenoid interlock with integrated AS-i Safety Interface_x000D_
  • Universal repeatedly teachable or individual coding because of the RFID technology_x000D_
  • I-variants with coding level HIGH to ISO 14119_x000D_
  • 2 integrated snap-in stages

Technical Specifications

PIN 1 AS-Interface +
PIN 2 Aux - (P)
PIN 3 AS-Interface -
PIN 4 Aux + (P)
Coding Individual coding
Category 4
General Note For doors flush with the door frame, the optional MP-AZ/AZM300-1 mounting plate can be used. For glass and Makrolon doors, the optional MS-AZ/AZM300-B1-1 mounting kit can be used.
PFD Value 2.34 x 10⁻⁴
PFH Value 1.34 x 10⁻⁹ /h
AS-i Profile S-7.B.F.E
Impact Resistance 30 g / 11 ms
Latching Yes
AS-i Version V 3.0
Emergency Exit Yes
Mission Time 20 Year(s)
Current Consumption 300 mA
Fuse Rating 0.16666666666787933
Gross Weight 646 g
Housing Material Cam elyaf takviyeli termoplastik
Protection Class III
Pollution Degree 3
Max. Relative Humidity 0.93
Note (Relative Humidity) Non-condensing, non-icing
Sensor Length 146 mm
Scope of Delivery Actuator additionally order must be.
Vibration Resistance 10 … 150 Hz, amplitude 0.35 mm
Force to Open Yes
Max. Risk Time 200 ms
AS-i Specification Safety Slave
AS-i Output DO 0 Solenoid control
AS-i Output DO 1 No function
AS-i Output DO 2 No function
AS-i Output DO 3 No function
IP Protection Class IP66 IP67 IP69
Max. Response Time 120 ms
Ambient Temperature +0 ... +60 °C
Performance Level e
RFID Frequency Band 125 kHz
Sensor Width 87.5 mm
Operating Voltage 24 VDC -15% / +10% (stabilized PELV power source)
Operating Principle RFID
Mechanical Life (min.) 1,000,000 Cycles
Note (Mechanical Life) When used as a door stop: ≥ 50,000 cycles (door mass ≤ 5 kg and actuation speed ≤ 0.5 m/s)
Sensor Height 55 mm
Recommendation (Actuator) AZ/AZM300-B1
AS-i Input Channel 1 Veri bitleri DI 0 / DI 1 = dinamik kod iletimi
AS-i Input Channel 2 Veri bitleri DI 2 / DI 3 = dinamik kod iletimi
Fixing Screw Type 2x M6
Terminal Connection M12 connector plug, 4 pole (A coded)
Suitable SIL Applications 3
Safety Functions Yes
Max. Installation Altitude 2,000 m
Max. Holding Force Fmax 1,500 N
Solenoid Lock Monitored Yes
AS-i Parameter Bits P0 Guard door closed and can be locked
AS-i Parameter Bits P1 Solenoid interlock locked
AS-i Parameter Bits P2 Auxiliary voltage in
AS-i Parameter Bits P3 Internal device error (FID)
Max. Ready Time 5,000 ms
Note (Performance Level) Information about the safety classification of the guard locking function can be found in the "Operating instructions" or "Use and mounting" instructions...
AS-i Max. Current Consumption 100 mA
Number of Actuation Directions 3
Note (Switching Distance) All switching distances EN IEC 60947-5-3'e is according to
Typical Switching Distance 2 mm
AS-i Input Module Address 0
Overvoltage Category III
Magnet Release Time 1
Rated Operating Voltage 24 VDC
Min. Fixing Screw Torque 6 Nm
Note (AS-i Parameter Bits) Set the parameter outputs to "1111" (0xF). FID: peripheral error
Note (Auxiliary DC Voltage) stabilized PELV power source
Guaranteed Opening Distance (ON) Sao 1 mm
Max. Fixing Screw Torque 7 Nm
Max. Transmitter RFID Output -6 dBm
Impulse Withstand Voltage (Uimp) 0.8 kV
Guaranteed Opening Distance (OFF) Sar 20 mm
Storage/Transport Temperature -10 ... +90 °C
Integrated System Diagnostics Status Yes
Locking Force Adjustment Position 1 25 N
Locking Force Adjustment Position 2 50 N
Coding Level (EN ISO 14119) High
Holding Force FZh (EN ISO 14119) 1,150 N
Rated Insulation Voltage (Uᵢ) 32 VDC
Note (AS-i Input Module Address) Adres 0'a front set; AS-interface bus master or el type programlama device with changeable
Note (LED Switching Condition Indication) (1) green/red LED (AS-i duo LED): Supply voltage/communication error/slave address=0/peripheral unit error/device error/tamper protection active (2) Yellow LED: Device status (Enable status) (3) Red LED: Internal...
Max. Solenoid Lock-Actuator Angular Misalignment 2 °