Order No
101123071
Article Code
101123071
Certificates
cULus
Schmersal
Emniyetli Anahtarlama ve Denetleme
Emniyet Sensörleri
BNS 250-12Z
Product Description
- • IP Rating: IP67 | Weight: 60 g | Cable: 1 m | Certification: cULus | Contacts: 2 NC, 1 NO
Standards
- • EN ISO 13849-1
Product Features
- • Termoplastik gövde_x000D_
- • Kompakt gövde_x000D_
- • Gizli montaj mümkün_x000D_
- • 33 mm x 25 mm x 13 mm_x000D_
- • Uzun ömürlü_x000D_
- • Mekanik aşınma yok_x000D_
- • Yanal hizasızlığa karşı duyarsız_x000D_
- • Kirlenmeye karşı duyarsız
Technical Specifications
Coding
Yes
General Note
Contact sembolleri, guard of the device closed condition for is shown. LED'li or LED'siz of the versions contact configuration is the same.
Active Area
front taraf
Wire Cross-Section
23 AWG
Impact Resistance
30 g / 11 ms
Mission Time
20 Year(s)
Direction of Movement
Active to the surface vertical
Cable Length
1 m
Gross Weight
60 g
Housing Material
Cam elyaf takviyeli termoplastik
Sensor Length
13 mm
Scope of Delivery
Actuator additionally order must be.
Vibration Resistance
10 … 150 Hz, amplitude 0.35 mm
Number of Cable Wires
4
Actuation Element
Magnet
IP Protection Class
IP67
Ambient Temperature
-25 ... +70 °C
Sensor Width
33 mm
Operating Principle
Magnetic drive
Switching Element
1 NA contact, 2 NK contact
Switching Principle
Reed contacts, non-contact prensip
Sensor Height
25 mm
Recommendation (Actuator)
BPS 250
B10D NC Contact Value
25,000,000 Cycles
Terminal Connection
Cable
B10D NC/NA Contact Value
25,000,000 Cycles
Cable Sheath Material
PVC
Max. Switching Current
0.1 A
Max. Switching Voltage
24 VDC
Mechanical Mounting Conditions
Embedded not
Note (Switching Distance)
All switching distances EN IEC 60947-5-3'e is according to
Max. Switching Capacity
1 W
Guaranteed Opening Distance (ON) Sao
4 mm
Guaranteed Opening Distance (OFF) Sar
14 mm
Storage/Transport Temperature
-25 ... +70 °C
Coding Level (EN ISO 14119)
Low
Recommended Safety Switch
SRB-E-301ST SRB-E-201LC
Precondition Evaluation Unit
Yes
Max. Switching Frequency (Approx.)
5 Hz
Number of NO (Normally Open) Contacts
1
Number of NC (Normally Closed) Contacts
2