Order No
101215518
Article Code
101215518
Certificates
cULus ECOLAB
Schmersal
Emniyetli Anahtarlama ve Denetleme
Emniyet Sensörleri
BNS 40S-12Z-C
Product Description
- • IP Rating: IP69 | Weight: 214 g | Cable: 1 m | Certification: cULus ECOLAB | Contacts: 2 NC, 1 NO
Standards
- • EN ISO 13849-1
Product Features
- • especially easy to clean through concealed threaded holes at the rear_x000D_
- • Stainless steel enclosure_x000D_
- • Cable connection suitable for the food industry_x000D_
- • Gizli montaj mümkün_x000D_
- • 88 mm x 27 mm x 14,5 mm_x000D_
- • Uzun ömürlü_x000D_
- • Mekanik aşınma yok_x000D_
- • Kirlenmeye karşı duyarsız_x000D_
- • Yanal hizasızlığa karşı duyarsız_x000D_
- • Suitable for food processing industry
Technical Specifications
Coding
Yes
General Note
Contact sembolleri, guard of the device closed condition for is shown. LED'li or LED'siz of the versions contact configuration is the same.
Active Area
Yanal
Cable Type
LiYY
Wire Cross-Section
23 AWG
Impact Resistance
30 g / 11 ms
Mission Time
20 Year(s)
Direction of Movement
Active to the surface vertical
Cable Length
1 m
Gross Weight
214 g
Housing Material
Stainless steel (V4A)
Sensor Length
14 mm
Scope of Delivery
Actuator additionally order must be.
Vibration Resistance
10 … 55 Hz, amplitude 1 mm
Number of Cable Wires
6
Actuation Element
Magnet
IP Protection Class
IP69
Ambient Temperature
-25 ... +80 °C
Sensor Width
88 mm
Operating Principle
Magnetic drive
Switching Element
1 NA contact, 2 NK contact
Switching Principle
Reed contacts, non-contact prensip
Sensor Height
27 mm
Recommendation (Actuator)
BPS 40S-2 BPS 40S-1-C BPS 40S-2-C BPS 40S-1
Terminal Connection
Cable
Connection Diagram Note
S21-S22 contact safety devresine integrated must be.
B10D NC/NA Contact Value
25,000,000 Cycles
Cable Sheath Material
PVC
Max. Switching Current
0.25 A
Max. Switching Voltage
100 VDC
Mechanical Mounting Conditions
Embedded not
Note (Switching Distance)
All switching distances EN IEC 60947-5-3'e is according to
Hidden Threaded Holes at the Rear
Yes
Max. Switching Capacity
3 W
Guaranteed Opening Distance (ON) Sao
8 mm
Guaranteed Opening Distance (OFF) Sar
18 mm
Storage/Transport Temperature
-25 ... +80 °C
Coding Level (EN ISO 14119)
Low
Recommended Safety Switch
SRB-E-301ST SRB-E-201LC
Precondition Evaluation Unit
Yes
Max. Switching Frequency (Approx.)
5 Hz
Number of NO (Normally Open) Contacts
1
Number of NC (Normally Closed) Contacts
2