Order No
101183762
Article Code
101183762
Certificates
cULus
Schmersal
Emniyetli Anahtarlama ve Denetleme
Solenoid Kilitler
AZM 170-02ZRKA-ST8 24VAC/DC
Product Description
- • IP Rating: IP67 | Weight: 278 g | Certification: cULus | PL d
Standards
- • EN ISO 13849-1
Product Features
- • Termoplastik gövde_x000D_
- • Çift yalıtımlı_x000D_
- • Kompakt tasarım_x000D_
- • Hatalı kilitlemeye karşı korumalı kilit_x000D_
- • Uzun ömürlü_x000D_
- • Yüksek tutma kuvveti
Technical Specifications
Note
Torx T10
Mounting
Vidalar
Category
3
General Note
Bu terminasyon (IDC) method, iletken end to the use of gerek kalmadan esnek iletkenlerin kolay connection provides
Application Note
Slide-mounted guard cover removable cover hinged guard cover
Mission Time
20 Year(s)
Please Note
Single channel mekanizmaya tehlikeli hasar for fault of excluding kabul edilebilir and to manipulation counter sufficient protection garanti that is done cases...
Gross Weight
278 g
Housing Material
Plastik, cam elyaf takviyeli termoplastik, automatically fading
Contact Material
Silver
Protection Class
II
Locking Force
30 N
Pollution Degree
3
Note (Relative Humidity)
Non-condensing, non-icing
Sensor Length
30 mm
Scope of Delivery
Actuator additionally order must be. Yuva sealing plugs
Manual Lock Release
Yes
Terminal (Mechanical)
M12 connector plug, 8 pole, A-coded
IP Protection Class
IP67
Ambient Temperature
-25 ... +60 °C
Performance Level
d
Sensor Width
90 mm
Thermal Test Current
0.08333333333212067
Operating Principle
Elektromekanik
Switching Element
2 NK contact
Switching Principle
Slow hareket, pozitif opening NK contact
Mechanical Life (min.)
1,000,000 Cycles
Note (B10D NA Contact)
%10 Ie and ohmic load for
Sensor Height
79 mm
B10D NA Contact Value
1,000,000 Cycles
B10D NC Contact Value
2,000,000 Cycles
Integrated M12 Connection
Yes
Force to Lock
Yes
Positive Opening Distance
11 mm
Fixing Screw Type
2x M4
Max. Actuation Speed
2 m/s
Max. Installation Altitude
2,000 m
Max. Test Pulse Duration
5 ms
Max. Holding Force Fmax
1,300 N
Rated Control Voltage
24 VAC/DC
Note (Manual Lock Release)
lower side
Number of Safety Contacts
2
Number of Actuation Directions
2
Current Utilization Cat. DC-13
0.08333333333212067
Min. Positive Opening Force
17 N
Min. Test Pulse Interval
50 ms
Note (Switching Element)
Dual kesimli changeover contact, type Zb or 2 NK contact, galvanik separated contact bridges with
Number of Auxiliary Contacts
1
Overvoltage Category
III
Max. Switching Frequency
1,000 /h
Magnet Release Time
1
Voltage Utilization Cat. DC-13
24 VDC
Impulse Withstand Voltage (Uimp)
4 kV
Storage/Transport Temperature
-25 ... +85 °C
Coding Level (EN ISO 14119)
Low
Increased Locking Force
Yes
Note (Utilization Category DC-13)
Connector 8-pin
Holding Force FZh (EN ISO 14119)
1,000 N
Max. Electrical Power Consumption
12 W
Min. Positive Opening Force/Contact
8.5 N
Rated Insulation Voltage (Uᵢ)
60 V
Housing Cover Screw Torque (Min.)
0.7 Nm
8-Pole Connector Impulse Voltage
0.8 kV
Required Rated Short-Circuit Current
1,000 A
Housing Cover Screw Torque (Max.)
1 Nm