Order No
103015314
Article Code
103015314
Certificates
TÜV cULus FCC IC ANATEL
Schmersal
Emniyetli Anahtarlama ve Denetleme
Solenoid Kilitler
AZM400Z-ST-1P2P-BOW
Product Description
- • IP Rating: IP66/IP67 | Voltage: 24 VDC | Weight: 764 g | PL e
Standards
- • EN ISO 13849-1 EN IEC 61508
Product Features
- • Universal coding with RFID technology_x000D_
- • Connector M12, 8-pole_x000D_
- • Kapı kilitleme izleniyor_x000D_
- • 1 Diagnostic output_x000D_
- • With securing holes for Bowden cable assembly_x000D_
- • Bistable, motor-driven system_x000D_
- • Clamping force 10.000_x000D_
- • Release possible against lateral forces up to 300 N_x000D_
- • PL e / cat. 4 / SIL 3 for interlocking and guard locking function_x000D_
- • Two-channel input signal of the guard locking function_x000D_
- • Operation on P/P- and P/N-switching outputs_x000D_
- • High tolerance to door misalignment
Technical Specifications
Note
Diagnostic outputs are not safety-related outputs!
PIN 1
A1 Supply voltage UB
PIN 2
E1 Kontrol input 1
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
OUTPUT Diagnostics output
PIN 6
E3 Kontrol input 3
PIN 7
Y2 Safety output 2
PIN 8
E2 Kontrol input 2
Coding
Universal coding
Category
4
PFD Value
1.60 x 10⁻⁴
PFH Value
1.80 x 10⁻⁹ /h
Impact Resistance
30 g / 11 ms
Mission Time
20 Year(s)
Gross Weight
764 g
Housing Material
Hafif alloy pressurized cast
Protection Class
III
Pollution Degree
3
Max. Relative Humidity
0.93
Note (Relative Humidity)
Non-condensing, non-icing
Sensor Length
46.7 mm
Scope of Delivery
Actuator and Bowden cable teslimata included is not. AZM400Z-...-BOW version only ACC-AZM400-BOW-.M-.M Bowden cable release with can be used. Bowden cable release fitted without usage kabul edilemez.
Vibration Resistance
10 … 150 Hz, amplitude 0.35 mm
Screw Tightening Torque
8 Nm
Locking Principle
bistable
IP Protection Class
IP66 IP67
Short-Circuit Detection
Yes
Ambient Temperature
-20 ... +55 °C
Performance Level
e
RFID Frequency Band
125 kHz
Sensor Width
77.8 mm
Operating Voltage
24 VDC -15% / +10% (stabilized PELV power source)
Operating Principle
Magnetic field RFID
Mechanical Life (min.)
1,000,000 Cycles
Note (Mechanical Life)
Which have a lateral force Ftrans = 100 N: 100.000 cycles
Sensor Height
156.7 mm
Recommendation (Actuator)
AZM400-B1
Cross-Circuit Detection
Yes
Fixing Screw Type
2x M6
Terminal Connection
Connector M12, 8-pole, A-coded
Max. Leakage Current (Ir)
0.5 mA
Suitable SIL Applications
3
24V Min. Current Consumption
5 mA
Safety Functions
Yes
Max. Installation Altitude
2,000 m
Max. Test Pulse Duration
0.5 ms
Max. Holding Force Fmax
13,000 N
Min. Distance Between Devices
30 mm
Solenoid Lock Monitored
Yes
24V Max. Current Consumption
10 mA
Number of Safety Contacts
2
Max. Ready Time
1,500 ms
Number of Diagnostic Signals
1
Current Utilization Cat. DC-12
0.05 A
Current Utilization Cat. DC-13
0.05 A
Utilization Category DC-12
24 VDC / 0.05 A
Overvoltage Category
III
Control Inputs Definition
E1 and E2 (p-switching), E3 (n-switching)
Max. Test Pulse Interval
40 ms
Rated Operating Voltage
24 VDC
Typical Test Pulse Interval
1000 ms
Voltage Utilization Cat. DC-12
24 VDC
Voltage Utilization Cat. DC-13
24 VDC
Note (Fixing Screw Type)
Mukavemet class min. 10,9
Max. Voltage Drop (Ud)
2 V
Max. Transmitter RFID Output
-6 dBm
Impulse Withstand Voltage (Uimp)
0.8 kV
Control Elements Design
Short devre resistant, p-type
Min. Lock-Actuator Distance
1 mm
Storage/Transport Temperature
-40 ... +85 °C
Integrated System Diagnostics Status
Yes
Coding Level (EN ISO 14119)
Low
Max. Lock-Actuator Distance
7 mm
Holding Force FZh (EN ISO 14119)
10,000 N
Safety Outputs Definition
Y1 and Y2
Max. Electrical Fuse Rating
0.08333333333212067
Rated Insulation Voltage (Uᵢ)
32 VDC
Diagnostic Outputs Definition
OUT
Max. Switching Frequency (Approx.)
0.3 Hz
Required Rated Short-Circuit Current
100 A
External Wire and Device Fuse Rating
2 A gG
ZVEI CB24I Sink Classification
C1 C2
Bowden Cable Fixing Screw Torque
1.2 Nm
Min. Open/Close Cycles (Motor)
3 s
ZVEI CB24I Source Classification
C2
Typical Idle Operating Current (I₀)
100 mA
Permissible Residual Drive Current
1.5 mA
Note (Bolt Return Lateral Force)
Acil exit, Bowden cable and manuel lock opening for valid not
Peak Current During Bolt Movement
600 mA / 100 ms
Control Inputs Switching Thresholds
−3 V … 5 V (Low) 15 V … 30 V (High)
Max. Lateral Force on Bolt Return
300 N
Note (LED Switching Condition Indication)
Operating status: LED green / Fault / functional failure: LED red / Supply voltage UB: LED green
Fixing Holes for Bowden Cable Mounting
Yes
Max. Permissible Discrepancy Time (Input)
10 s
Max. Solenoid Lock-Actuator Angular Misalignment
2 °
Min. Average Cycle Time (Continuous Operation)
20 s
Max. Response Time (Actuator to Safety Output Off)
100 ms