BNS 250-11ZG 5,0M
Order No 101125073
Article Code 101125073
Certificates cULus
Schmersal Emniyetli Anahtarlama ve Denetleme Emniyet Sensörleri

BNS 250-11ZG 5,0M

Product Description

  • IP Rating: IP67 | Weight: 190 g | Cable: 5 m | Certification: cULus | Contacts: 1 NC, 1 NO

Standards

  • EN ISO 13849-1

Product Features

  • Termoplastik gövde_x000D_
  • Kompakt gövde_x000D_
  • Gizli montaj mümkün_x000D_
  • 33 mm x 25 mm x 13 mm_x000D_
  • Uzun ömürlü_x000D_
  • Mekanik aşınma yok_x000D_
  • Yanal hizasızlığa karşı duyarsız_x000D_
  • Kirlenmeye karşı duyarsız

Technical Specifications

Coding Yes
General Note Contact sembolleri guard of the device closed condition for is shown. LED'li/LED'siz of the versions contact configuration is the same.
Active Area front taraf
Wire Cross-Section 23 AWG
Impact Resistance 30 g / 11 ms
Mission Time 20 Year(s)
Direction of Movement Active to the surface vertical
Cable Length 5 m
Gross Weight 190 g
Housing Material Cam elyaf takviyeli termoplastik
Sensor Length 13 mm
Scope of Delivery Actuator additionally order must be.
Vibration Resistance 10 … 150 Hz, amplitude 0.35 mm
Number of Cable Wires 4
Actuation Element Magnet
IP Protection Class IP67
Ambient Temperature -25 ... +70 °C
Sensor Width 33 mm
Operating Principle Magnetic drive
Switching Element 1 NA contact, 1 NK contact
Switching Principle Reed contacts, non-contact prensip
Sensor Height 25 mm
Recommendation (Actuator) BPS 250
B10D NC Contact Value 25,000,000 Cycles
Terminal Connection Cable
B10D NC/NA Contact Value 25,000,000 Cycles
Cable Sheath Material PVC
Max. Switching Current 0.01 A
Max. Switching Voltage 24 VDC
Mechanical Mounting Conditions Embedded not
Note (Switching Distance) All switching distances EN IEC 60947-5-3'e is according to
Max. Switching Capacity 0.24 W
Guaranteed Opening Distance (ON) Sao 4 mm
Guaranteed Opening Distance (OFF) Sar 14 mm
Storage/Transport Temperature -25 ... +70 °C
Integrated System Diagnostics Status Yes
Coding Level (EN ISO 14119) Low
Recommended Safety Switch SRB-E-301ST SRB-E-201LC
Precondition Evaluation Unit Yes
Max. Switching Frequency (Approx.) 5 Hz
Number of NO (Normally Open) Contacts 1
Number of NC (Normally Closed) Contacts 1
Note (Integrated System Diagnostics Status) LED lights up when the guard door is open.