Order No
101211068
Article Code
101211068
Certificates
TÜV cULus
Schmersal
Emniyetli Anahtarlama ve Denetleme
Solenoid Kilitler
MZM 100 B ST-1P2PW2RE-A
Product Description
- • IP Rating: IP65/IP67 | Voltage: 24 VDC | Weight: 645 g | PL e
Standards
- • EN ISO 13849-1 EN IEC 61508
Product Features
- • Actuator monitored_x000D_
- • Connector M23, 8+1-pole_x000D_
- • Kilitlemek için güç gerekli_x000D_
- • Solenoid interlocks with innovating and unique operating principle_x000D_
- • 40 mm x 179 mm x 40 mm_x000D_
- • Elektronik temazsız kodlu sistem_x000D_
- • Termoplastik gövde_x000D_
- • Sensör zincirinin maks. uzunluğu 200 m_x000D_
- • Çalışma koşullarını gösteren 3 LED_x000D_
- • Sensör teknolojisi aktüatör ve kilit arasında ±5 mm dikey ve ±1,5 mm yatay ofset sağlar_x000D_
- • Akıllı diagnostik_x000D_
- • Kendinden izlemeli seri kablolama
Technical Specifications
PIN 1
A1 Supply voltage UB
PIN 2
X1 Safety input 1
PIN 3
A2 GND
PIN 4
Y1 Safety output 1
PIN 5
OUTPUT Diagnostics output
PIN 6
X2 Safety input 2
PIN 7
Y2 Safety output 2
PIN 8
INPUT Solenoid control
PIN 9
fonksiyonsuz
Coding
Universal coding
Category
4
General Note
Actuation unit solenoid lock on applied as long as, lock opened safety protection again can be locked.
PFH Value
3.54 x 10⁻⁹ /h
Impact Resistance
30 g / 11 ms
Latching
Yes
Mission Time
20 Year(s)
Series Connection
Yes
Gross Weight
645 g
Housing Material
Plastik, cam elyaf takviyeli termoplastik, automatically fading
Protection Class
III
Min. Relative Humidity
0.3
Pollution Degree
3
Max. Relative Humidity
0.95
Note (Relative Humidity)
Non-condensing, non-icing
Sensor Length
40 mm
Scope of Delivery
Actuator additionally order must be.
Vibration Resistance
10 … 150 Hz, amplitude 0.35 mm / 5 g
Max. Risk Time
150 ms
Operating Current
1,100 mA
24V Current Consumption
5 mA
IP Protection Class
IP65 IP67
Short-Circuit Detection
Yes
Max. Response Time
150 ms
Ambient Temperature
-25 ... +55 °C
Performance Level
e
Sensor Width
40 mm
Typical Holding Force
750 N
Operating Voltage
24 VDC -15% / +10% (stabilized PELV power source)
Operating Principle
inductive
Actuator Monitored
Yes
Mechanical Life (min.)
1,000,000 Cycles
Note (Mechanical Life)
Actuating speed ≤ 0.5 m/s Cycles for door weights ≤ 5 kg
Sensor Height
179 mm
Recommendation (Actuator)
MZM 100-B1.1
Switching Thresholds
−3 V … 5 V (Low) 15 V … 30 V (High)
Note (Series Connection)
Unlimited number of devices; observe the external line fuse; max. 31 devices when using serial diagnostics (SD)
Cross-Circuit Detection
Yes
Force to Lock
Yes
Min. Locking Force
30 N
Fixing Screw Type
2x M6
Terminal Connection
Connector M23, 8+1-pole
Guaranteed Holding Force
500 N
Max. Leakage Current (Ir)
0.5 mA
Max. Locking Force
100 N
Suitable SIL Applications
3
Safety Functions
Yes
Max. Installation Altitude
2,000 m
Max. Test Pulse Duration
1 ms
Number of Safety Contacts
2
Max. Ready Time
4,000 ms
Current Utilization Cat. DC-13
0.05 A
Min. Test Pulse Interval
100 ms
Note (Switching Distance)
All switching distances EN IEC 60947-5-3'e is according to
Overvoltage Category
III
Magnet Release Time
1
Rated Operating Voltage
24 VDC
Typical Test Pulse Interval
1000 ms
Voltage Utilization Cat. DC-13
24 VDC
Guaranteed Opening Distance (ON) Sao
0 mm
Safety Inputs Definition
X1 and X2
Max. Voltage Drop (Ud)
2 V
Magnet Control Definition
IN
Impulse Withstand Voltage (Uimp)
0.8 kV
Guaranteed Opening Distance (OFF) Sar
1 mm
Control Elements Design
Short devre resistant, p-type
Fixing Screw Tightening Torque
8 Nm
Storage/Transport Temperature
-25 ... +70 °C
Integrated System Diagnostics Status
Yes
Coding Level (EN ISO 14119)
Low
Max. Sensor Chain Length
200 m
Note (Sensor Chain Length)
Cable length and cross-section change the voltage drop depending on the output current
Safety Outputs Definition
Y1 and Y2
Rated Insulation Voltage (Uᵢ)
32 VDC
Diagnostic Outputs Definition
OUT
Max. Switching Frequency (Approx.)
1 Hz
Required Rated Short-Circuit Current
100 A
External Wire and Device Fuse Rating
2 A gG
Magnet ON Peak Current Consumption
550 mA / 10 ms
ZVEI CB24I Sink Classification
C1
ZVEI CB24I Source Classification
C1
Magnet ON Average Current Consumption
350 mA
Typical Idle Operating Current (I₀)
100 mA
Note (LED Switching Condition Indication)
Operating status: LED green / Fault / functional failure: LED red / Supply voltage UB: LED green
Rated Operating Current (Safety Outputs)
250 mA