Order No
103016240
Article Code
103016240
Certificates
cULus
Schmersal
Emniyetli Sinyal İşleme
Emniyet Işık Perdeleri ve Izgaraları (SLC/SLG)
SLC240COM-ER-1370-14
Product Description
- • IP Rating: IP67 | Voltage: 24 VDC | Weight: 2,240 g | Certification: cULus | PL c
Standards
- • EN ISO 13849-1 EN IEC 62061
Product Features
- • IEC 61496-1'e göre güvenlik tipi 2_x000D_
- • Kullanıcı dostu parametre ayarı, alet gerekmez_x000D_
- • Reliable safety concept in case of interferences (EMC, welding sparks)_x000D_
- • En yüksek erişilebilirlikle proses güvenliği_x000D_
- • Aktif entegre kurulum aracı
Technical Specifications
Note
Fault in case of leakage current OSSD kablosuna akar. Down in the current kontrol element bu status LOW as must recognize. A safe PLC bu status tespit etmelidir.
PIN 1
24 VDC power source
PIN 2
Test Input testi
PIN 3
0 VDC power source
PIN 4
Slave Series connection
PIN 5
Reset Again start lock (manuel reset)
Category
2
Connection
Emitter
LED Status
OSSD OPEN, OSSD KAPALI, Again start lock, Hata, Parametre adjustment, Hizalama kit, Sinyal kalitesi display
LED Position
Receiver
PFH Value
8.05 x 10⁻⁹ /h
Impact Resistance
10 g, 16 ms, EN 60028-2-29'a according to
Mission Time
20 Year(s)
Number of Beams
136
Gross Weight
2,240 g
Housing Material
Aluminium
Protection Class
III
Sensor Length
33 mm
Scope of Delivery
2 mounting angle containing set
Vibration Resistance
10 … 55 Hz
IP Protection Class
IP67
Max. Response Time
20 ms
Ambient Temperature
-10 ... +50 °C
Performance Level
c
Sensor Width
27.8 mm
Switching Voltage
15 … 26,4 V (HIGH) 0 … 2 V (LOW)
Cascadable
Yes
Sensor Height
1,411 mm
Switching Thresholds
24 V (HIGH) 0 V (LOW)
Max. Load Capacity
0.05 µF
Laser Diode Wavelength
880 nm
Terminal Connection
Connector
Max. Leakage Current (Ir)
1 mA
Max. Load Inductance
2 H
Suitable SIL Applications
1
Integrated System Diagnostics
Yes
Max. Test Pulse Duration
0.15 ms
Note (Software Version)
2017 as of Version 1.0
Protection Zone Height
1,370 mm
Terminal Connector Transmitter
M12 connector plug, 4 pole
Control Inputs Definition
Reset and Test
Min. Protection Zone Distance
0.3 m
Rated Operating Voltage
24 VDC
Terminal Connector Receiver
M12 connector plug, 5 pole
Typical Test Pulse Interval
750 ms
Safety Type (IEC 61496-1)
2
Max. Protection Zone Distance
7 m
Master or Slave Function
Yes
Control Elements Design
OSSD, short devre resistant, p-type
Storage/Transport Temperature
-25 ... +70 °C
Integrated System Diagnostics Status
Yes
Recommended Safety Switch
SRB-E 301
Safety Outputs Definition
OSSD 1 and OSSD 2
Receiver Rated Operating Current
700 mA
Emitter Rated Operating Current
200 mA
Test Object Detection (v≤1.6 m/s)
14 mm
Number of Safe Digital Outputs
2
Max. Connectable Cable Length
100 m
Manual Start Actuation Time
100 … 1500 ms
ZVEI CB24I Sink Classification
C1 C2
ZVEI CB24I Source Classification
C2
Radiation Emission Level (EN 12198-1)
Kategori 0
Restart Lockout (Manual Reset)
Yes
Zone Deactivation Function
Yes
Max. Output Current (Safe Output)
0.25 A
Lamp Systems Risk Group Classification (EN 62471)
free group