Order No
103006151
Article Code
103006151
Certificates
TÜV cULus CCC TILVA
Schmersal
Emniyetli Sinyal İşleme
Güvenlik İzleme Modülleri
SRB301ST-24V-(V.2)
Product Description
- • Voltage: 24 VDC | Dimensions: 22.5mm×120mm×121mm | Weight: 280 g | Contacts: 2 NC
Standards
- • EN ISO 13849-1 EN IEC 62061 EN IEC 61508
Product Features
- • Suitable for the signal processing of outputs with contact sensors_x000D_
- • Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains_x000D_
- • 3 güvenlik kontağı, STOP 0_x000D_
- • 1 sinyal çıkışı
Technical Specifications
Mounting
Fits onto a standard DIN rail per EN 60715
Warning
Discontinued product
Depth
121 mm
General Note
Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width
22.5 mm
SIL Stop 0
3
Height
120 mm
Number of LEDs
5
Impact Resistance
10 g / 11 ms
EMC Class
EMC Directive
Application Note
Safety sensor Protection system Acil durdurma butonu Pull wire acil durdurma switch Safety light bariyerleri
Mission Time
20 Year(s)
Category Stop 0
4
Gross Weight
280 g
Housing Material
Glass-fibre reinforced thermoplastic, ventilated
Contact Material
AgSn0. self-cleaning, positive drive
Start Input
Yes
Pollution Degree
2
Min. Cable Cross-Section
0.25 mm²
Vibration Resistance
10 ... 55 Hz, Amplitude 0.35 mm
DC Level Stop 0
≥ 99 %
Electronic Fuse
Yes
Frequency Range
50 Hz 60 Hz
Clip Tightening Torque
0.6 Nm
Max. Cable Cross-Section
2.5 mm²
PFH Value Stop 0
2.00 x 10⁻⁸ /h
Terminal (Mechanical)
Removable threaded terminaller
Climatic Resistance
EN 60068-2-78
Ripple Voltage
0.1
Stop Category
0
Ambient Temperature
-25 ... +60 °C
Reset Edge Detection
Yes
Operating Voltage
24 VAC -15 % / +10 % 24 VDC -15 % / +40 %
Feedback Circuit
Yes
IP Protection (Housing)
IP40
Max. Contact Resistance
0.1 Ω
Mechanical Life (min.)
10,000,000 Cycles
Note (Contact Resistance)
In new condition
Terminal Definitions
IEC/EN 60947-1
Max. Transmission Resistance
40 Ω
Wire Breakage Detection
Yes
Cross-Circuit Detection
Yes
Connection Diagram Note
Connection diagram, guard door closed and enerji cut off in the state is shown. nQS (upper): cross cable protection yok. QS (alt taraf): cross cable protection. Automatic start S12/X3 terminallerine by connecting is programmed. F1 = Hybrid fuse
Max. Installation Altitude
2,000 m
Permissible Cable Type
Single core solid / esnek
Number of Safety Contacts
3
IP Protection (Mounting Area)
IP54
Automatic Reset Function
Yes
Current Utilization Cat. AC-15
0.25
Current Utilization Cat. DC-13
0.25
Performance Level Stop 0
e
Number of Auxiliary Contacts
1
Overvoltage Category
III
Electrical Power Consumption
4.9 VA
Min. Switching Capacity
10 mA
Rated Operating Voltage
24 VDC
AC Control Voltage 50Hz min.
20.4 VAC
AC Control Voltage 60Hz min.
20.4 VAC
Voltage Utilization Cat. AC-15
230 VAC
Voltage Utilization Cat. DC-13
24 VDC
IP Protection (Terminal Block)
IP20
Max. Switching Capacity
0.08333333333212067
Earth Connection Detection
Yes
Removable Terminals
Yes
AC Control Voltage 50Hz max.
26.4 VAC
AC Control Voltage 60Hz max.
26.4 VAC
Impulse Withstand Voltage (Uimp)
4 kV
Emergency Release Delay
25 ms
Storage/Transport Temperature
-40 ... +85 °C
Integrated System Diagnostics Status
Yes
Pull-In Delay After RESET
15 ms
DC Min. Rated Control Voltage
20.4 VDC
Min. Common Cause Failure (CCF)
65
DC Max. Rated Control Voltage
28.8 VDC
Displayed Operating States
Konum relay K2 Konum relay K1 Internal operation voltage U i Operation voltage U B
Emergency Stop Release Delay (Max.)
32 ms
Release Delay on Power Failure
100 ms
Number of NC (Normally Closed) Contacts
2
Pull-In Delay on Automatic Start
100 ms
Note (LED Switching Condition Indication)
QS: cross-wire short detection status (LED on when cross-wire short detection active).