SRB400CS/T 24VDC
Order No 101176211
Article Code 101176211
Certificates cULus
Schmersal Emniyetli Sinyal İşleme Güvenlik İzleme Modülleri

SRB400CS/T 24VDC

Product Description

  • Voltage: 24 VDC | Dimensions: 22.5mm×100mm×121mm | Weight: 235 g | Certification: cULus

Standards

  • EN IEC 60947-5-1 EN IEC 61508

Product Features

  • Level 1: Reset with edge detection, Level 2: / Opener (NC) Opener (NC)_x000D_
  • Two-functions safety monitoring module (double evaluation)_x000D_
  • 2 x 2 enabling paths with different shut-down behaviour, e.g. emergency exit opens both enabling paths (level 1); guard door monitoring only opens the second enabling path (level 2)_x000D_
  • Suitable for signal processing of potential-free contacts, e.g. Emergency Stop command devices (level 1), position switches with safety function, solenoid interlocks and safety sensors (level 2)

Technical Specifications

Mounting Fits onto a standard DIN rail per EN 60715
Warning Discontinued product
Depth 121 mm
General Note Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width 22.5 mm
SIL Stop 0 3
Height 100 mm
Number of LEDs 6
Impact Resistance 10 g / 11 ms
EMC Class EMC Directive
Application Note Safety sensor Protection system Acil durdurma butonu Pull wire acil durdurma switch
Mission Time 20 Year(s)
Category Stop 0 4
Gross Weight 235 g
Housing Material Glass-fibre reinforced thermoplastic, ventilated
Contact Material Ag-Ni, self-cleaning, positive drive
Start Input Yes
Pollution Degree 2
Min. Cable Cross-Section 0.25 mm²
Vibration Resistance 10 ... 55 Hz, Amplitude 0.35 mm
DC Level Stop 0 ≥ 99 %
Electronic Fuse Yes
Clip Tightening Torque 0.6 Nm
Max. Cable Cross-Section 2.5 mm²
Number of NO Inputs 2
Number of NC Inputs 2
PFH Value Stop 0 2.00 x 10⁻⁸ /h
Terminal (Mechanical) Threaded terminal block
Climatic Resistance EN 60068-2-78
Ripple Voltage 0.1
Stop Category 0
Ambient Temperature -25 ... +45 °C
Reset Edge Detection Yes
Operating Voltage 24 VDC -10 % / +20 %
Feedback Circuit Yes
IP Protection (Housing) IP40
Max. Contact Resistance 0.1 Ω
Mechanical Life (min.) 10,000,000 Cycles
Note (Contact Resistance) In new condition
Terminal Definitions IEC/EN 60947-1
Max. Transmission Resistance 40 Ω
Wire Breakage Detection Yes
Spare Article Number 101177161
Connection Diagram Note Connection diagram, guard door closed and enerji cut off in the state is shown. Relay exit 2 channel control is suitable. Automatic start X1/X2 terminallerine by connecting is programmed. Feedback supply circuit if not required bridge is established.
Permissible Cable Type Single core solid / esnek
Number of Safety Contacts 4
IP Protection (Mounting Area) IP54
Current Utilization Cat. AC-15 0.25
Current Utilization Cat. DC-13 0.25
Performance Level Stop 0 e
Overvoltage Category III
Electrical Power Consumption 4.4 W
Min. Switching Capacity 10 mA
Rated Operating Voltage 24 VDC
Note (Cross-Circuit Detection) Seviye 1
Voltage Utilization Cat. AC-15 250 VAC
Voltage Utilization Cat. DC-13 24 VDC
IP Protection (Terminal Block) IP20
Max. Switching Capacity 0.08333333333212067
Earth Connection Detection Yes
Removable Terminals Yes
Impulse Withstand Voltage (Uimp) 4 kV
Emergency Release Delay 20 ms
Storage/Transport Temperature -40 ... +85 °C
Integrated System Diagnostics Status Yes
Pull-In Delay After RESET 20 ms
DC Min. Rated Control Voltage 20.4 VDC
Min. Common Cause Failure (CCF) 65
DC Max. Rated Control Voltage 28.8 VDC
Displayed Operating States Konum relay K2 Konum relay K1 Internal operation voltage U i Konum relay K3
Release Delay on Power Failure 80 ms
Pull-In Delay on Automatic Start 100 ms
Opening Delay on Automatic Start Adjustable