SLC440-ER-0330-14-01
Order No 101216617
Article Code 101216617
Certificates TÜV cULus ECOLAB
Schmersal Emniyetli Sinyal İşleme Emniyet Işık Perdeleri ve Izgaraları (SLC/SLG)

SLC440-ER-0330-14-01

Product Description

  • IP Rating: IP67 | Voltage: 24 VDC | Weight: 730 g | PL e

Standards

  • EN ISO 13849-1 EN IEC 62061

Product Features

  • IEC 61496-1'e göre güvenlik tipi 4_x000D_
  • Bluetooth ile uygulama üzerinden durum ve diagnostik_x000D_
  • Aktif entegre kurulum aracı_x000D_
  • Blanking: fixed/floating_x000D_
  • Double acknowledgement/reset_x000D_
  • Integrated contactor control_x000D_
  • Beam coding_x000D_
  • En yüksek erişilebilirlikle proses güvenliği_x000D_
  • Kullanıcı dostu parametre ayarı, alet gerekmez_x000D_
  • Koruyucu muhafaza ile isteğe bağlı IP69 koruma sınıfı (aksesuar)

Technical Specifications

Note Fault in case of leakage current OSSD kablosuna akar. Down in the current kontrol element bu status LOW as must recognize. A safe PLC bu status tespit etmelidir.
PIN 1 24 VDC power source
PIN 2 COD1 Coding 1
PIN 3 0 VDC power source
PIN 4 COD2 Coding 2
PIN 5 Restart 2 Acknowledgement again start lock 2
PIN 6 DOUT Operation Modu
PIN 7 0 VDC power source
PIN 8 Contactor control - EDM input
Category 4
Bluetooth Yes
Connection Emitter
LED Status transmission and state
LED Position Emitter
PFH Value 5.14 x 10⁻⁹ /h
Impact Resistance 10 g, 16 ms, EN 60028-2-29'a according to
Application Note automatic mod, again start lock, dual reset, contactor control, sabit and hareketli beam susturma, beam coding A
Mission Time 20 Year(s)
Current Consumption 3 … 10 mA (HIGH) 0 … 2 mA (LOW)
Number of Beams 32
Gross Weight 730 g
Housing Material Aluminium
Protection Class III
Sensor Length 33 mm
Scope of Delivery 2 mounting angle containing set
Vibration Resistance 10 … 55 Hz
Terminal (Mechanical) metal threaded with
7-Segment Display Yes
IP Protection Class IP67
Max. Response Time 10 ms
Ambient Temperature -25 ... +50 °C
Performance Level e
Sensor Width 27.8 mm
Transmitter Height 411 mm
Receiver Height 421 mm
Switching Voltage 15 … 26,4 V (HIGH) 0 … 2 V (LOW)
Switching Thresholds 11 … 30 V (HIGH) 0 … 2 V (LOW)
Max. Load Capacity 2.2 µF
Max. Transmission Resistance 2.5 Ω
Laser Diode Wavelength 880 nm
Terminal Connection Connector
Max. Leakage Current (Ir) 1 mA
Max. Load Inductance 2 H
Suitable SIL Applications 3
Integrated System Diagnostics Yes
Beam Coding Available Yes
Max. Test Pulse Duration 0.1 ms
Note (Software Version) 2021 as of Version 3.1
Protection Zone Height 330 mm
Terminal Connector Transmitter M12 connector plug, 4 pole
Bluetooth Transmission Frequency 2.400 … 2.483 GHz
Control Inputs Definition Serbest release/again start and Again start 2
Min. Protection Zone Distance 0.3 m
Rated Operating Voltage 24 VDC
Terminal Connector Receiver M12 connector plug, 8 pole
Typical Test Pulse Interval 750 ms
Integrated Contactor Control Yes
Safety Type (IEC 61496-1) 4
Max. Protection Zone Distance 7 m
Control Elements Design OSSD, short devre resistant, p-type
Max. Bluetooth Transmission Power 2 µW
Storage/Transport Temperature -25 ... +70 °C
Integrated System Diagnostics Status Yes
Min. Protection Zone Height 3 mm
Recommended Safety Switch SRB-E 301
Safety Outputs Definition OSSD 1 and OSSD 2
Receiver Rated Operating Current 700 mA
Emitter Rated Operating Current 200 mA
Test Object Detection (v≤1.6 m/s) 14 mm
Number of Safe Digital Outputs 2
Max. Connectable Cable Length 100 m
Manual Start Actuation Time 50 … 1500 ms
ZVEI CB24I Sink Classification C1 C2 C3
ZVEI CB24I Source Classification C3
Max. Response Time of External Devices 500 ms
Radiation Emission Level (EN 12198-1) Kategori 0
Restart Lockout (Manual Reset) Yes
Zone Deactivation Function Yes
Max. Output Current (Safe Output) 0.25 A
Contactor Control EDM Definition (Feedback Circuits) Contactor control
Lamp Systems Risk Group Classification (EN 62471) free group
shopping_cart

Quote Cart

shopping_cart

Your cart is empty.

You can add products from product pages.

compare_arrows Compare 0 / 3