Order No
101170041
Article Code
101170041
Certificates
cULus
Schmersal
Emniyetli Sinyal İşleme
Güvenlik Rölesi ve Kontrol Modülleri
AES 1155
Product Description
- • Voltage: 24 VDC | Dimensions: 22.5mm×100mm×121mm | Weight: 215 g | Certification: cULus | Contacts: 2 NC, 2 NO | PL d
Standards
- • EN ISO 13849-1 EN IEC 61508
Product Features
- • BNS serisi manyetik güvenlik sensörü izleme_x000D_
- • 1 güvenlik kontağı, STOP 0
Technical Specifications
Mounting
Fits onto a standard DIN rail per EN 60715
Warning
maks. 50.000 switching cycle/year and maks. %80 contact load for
Depth
121 mm
Category
3
Faults
Safety of the relay not pulling or not releasing; Door contact not opening or not closing; Switch connection cross cable or short devre monitoring; Switch connection kesilmesi; Safety monitoring of the module input devrelerinde or relay kontrol devrelerinde fault; Safety in the relay fault or fonksiyon error
General Note
Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width
22.5 mm
Height
100 mm
PFH Value
1.00 x 10⁻⁷ /h
Number of LEDs
1
Impact Resistance
30 g / 11 ms
EMC Class
EMC Directive
Application Note
Safety sensor Guard system
Mission Time
20 Year(s)
Gross Weight
215 g
Housing Material
Glass-fibre reinforced thermoplastic, ventilated
Contact Material
Ag-Ni 10 and 0,2 µm gold coated
Pollution Degree
2
Min. Cable Cross-Section
0.25 mm²
Vibration Resistance
10...55 Hz, Amplitude 0.35 mm, ± 15 %
Frequency Range
50 Hz 60 Hz
Clip Tightening Torque
0.6 Nm
Max. Cable Cross-Section
2.5 mm²
Terminal (Mechanical)
Threaded terminal block
Climatic Resistance
EN 60068-2-3 BG-GS-ET-14
Ripple Voltage
0.1
Stop Category
0
Ambient Temperature
+0 ... +55 °C
Performance Level
d
Thermal Test Current
0.25
Operating Voltage
24 VAC -15 % / +10 % 24 VDC -15 % / +40 %
IP Protection (Housing)
IP40
Max. Contact Resistance
0.1 Ω
Mechanical Life (min.)
20,000,000 Cycles
Note (Contact Resistance)
In new condition
Terminal Definitions
IEC/EN 60947-1
Reset When Power is Removed
Yes
Max. Transmission Resistance
40 Ω
Note (ISD - Faults)
The following fault safety monitoring modules by kaydedilir and ISD by is shown.
Wire Breakage Detection
Yes
Cross-Circuit Detection
Yes
Suitable SIL Applications
2
Connection Diagram Note
Rotary guard system minimum actuation radius 150 mm. Hinged in guards minimum actuation radius 350 mm. Hinge axis 28 mm above must be.
Permissible Cable Type
Single core solid / esnek
Number of Safety Contacts
1
IP Protection (Mounting Area)
IP54
Automatic Reset Function
Yes
Current Utilization Cat. AC-15
0.25
Current Utilization Cat. DC-12
0.1 A
Current Utilization Cat. DC-13
0.25
Overvoltage Category
III
Electrical Power Consumption
5 W
Min. Switching Capacity
10 mA
Rated Operating Voltage
24 VDC
AC Control Voltage 50Hz min.
20.4 VAC
AC Control Voltage 60Hz min.
20.4 VAC
Voltage Utilization Cat. AC-15
230 VAC
Voltage Utilization Cat. DC-12
24 VDC
Voltage Utilization Cat. DC-13
24 VDC
IP Protection (Terminal Block)
IP20
Max. Switching Capacity
0.08333333333212067
Earth Connection Detection
Yes
AC Control Voltage 50Hz max.
26.4 VAC
AC Control Voltage 60Hz max.
26.4 VAC
Input Signal LOW (Signal 0)
0 … 2 VDC
Impulse Withstand Voltage (Uimp)
4 kV
Input Signal HIGH (Signal 1)
10 … 30 VDC
Emergency Release Delay
20 ms
Storage/Transport Temperature
-25 ... +70 °C
Integrated System Diagnostics Status
Yes
Pull-In Delay After RESET
20 ms
DC Min. Rated Control Voltage
20.4 VDC
DC Max. Rated Control Voltage
28.8 VDC
Number of NO (Normally Open) Contacts
2
Release Delay on Power Failure
80 ms
Number of NC (Normally Closed) Contacts
2
Pull-In Delay on Automatic Start
100 ms
Number of Undelayed Semiconductor Outputs (with Signal Function)
2