Order No
101180842
Article Code
101180842
Certificates
cULus
Schmersal
Emniyetli Sinyal İşleme
Güvenlik İzleme Modülleri
AES 2135 UE: 24...230V AC/DC
Product Description
- • Voltage: 24 ... 230 VAC | Dimensions: 45mm×100mm×121mm | Weight: 280 g | Certification: cULus | Contacts: 2 NC, 1 NO | PL d
Standards
- • EN ISO 13849-1 EN IEC 61508
Product Features
- • BNS serisi manyetik güvenlik sensörü izleme_x000D_
- • 1 güvenlik kontağı, STOP 0_x000D_
- • 2 sinyal çıkışı
Technical Specifications
Mounting
Fits onto a standard DIN rail per EN 60715
Warning
Discontinued product
Depth
121 mm
Category
3
Faults
Safety of the relay not pulling or not releasing; Door contact not opening or not closing; Switch connection cross cable or short devre monitoring; Switch connection kesilmesi; Safety monitoring of the module input devrelerinde or relay kontrol devrelerinde fault; Safety in the relay fault or fonksiyon error
General Note
Inductive loads (e.g. contactors, relays, etc.) must be suppressed with a suitable circuit.
Width
45 mm
Height
100 mm
PFH Value
1.00 x 10⁻⁷ /h
Number of LEDs
1
Impact Resistance
30 g / 11 ms
EMC Class
EMC Directive
Application Note
Safety sensor Guard system
Mission Time
20 Year(s)
Gross Weight
280 g
Housing Material
Cam elyaf takviyeli termoplastik
Contact Material
Ag-Ni, Au
Pollution Degree
2
Min. Cable Cross-Section
0.25 mm²
Vibration Resistance
10...55 Hz, Amplitude 0.35 mm, ± 15 %
Frequency Range
50 Hz 60 Hz
Clip Tightening Torque
0.6 Nm
Max. Cable Cross-Section
2.5 mm²
Terminal (Mechanical)
Threaded terminal block
Climatic Resistance
BG-GS-ET-14 IEC 60947-5-3
Stop Category
0
Ambient Temperature
+0 ... +55 °C
Performance Level
d
Thermal Test Current
0.16666666666787933
Operating Voltage
24 ... 230 VAC 24 ... 230 VDC
IP Protection (Housing)
IP40
Max. Contact Resistance
0.1 Ω
Mechanical Life (min.)
50,000,000 Cycles
Note (Contact Resistance)
In new condition
Terminal Definitions
IEC/EN 60947-1
Reset When Power is Removed
Yes
Max. Transmission Resistance
40 Ω
Note (ISD - Faults)
The following fault safety monitoring modules by kaydedilir and ISD by is shown.
Wire Breakage Detection
Yes
Cross-Circuit Detection
Yes
Voltage Range Type
AC DC
Suitable SIL Applications
2
Connection Diagram Note
Connection diagram, guard door closed and enerji cut off in the state is shown. PL d and Category 3'e up to a the guard door assurance below securing for.
Permissible Cable Type
Single core solid / esnek
Number of Safety Contacts
1
IP Protection (Mounting Area)
IP54
Automatic Reset Function
Yes
Current Utilization Cat. AC-15
0.125
Current Utilization Cat. DC-12
0.1 A
Current Utilization Cat. DC-13
0.08333333333212067
Overvoltage Category
III
Electrical Power Consumption
5 W
Min. Switching Capacity
10 mA
Rated Operating Voltage
24 ... 230 VAC 24 ... 230 VDC
Number of Signal Outputs
2
AC Control Voltage 50Hz min.
20.4 VAC
AC Control Voltage 60Hz min.
20.4 VAC
Voltage Utilization Cat. AC-15
230 VAC
Voltage Utilization Cat. DC-12
24 VDC
Voltage Utilization Cat. DC-13
24 VDC
IP Protection (Terminal Block)
IP20
Max. Switching Capacity
0.08333333333212067
AC Control Voltage 50Hz max.
253 VAC
AC Control Voltage 60Hz max.
253 VAC
Input Signal LOW (Signal 0)
0 … 2 VDC
Impulse Withstand Voltage (Uimp)
4 kV
Input Signal HIGH (Signal 1)
10 … 30 VDC
Emergency Release Delay
20 ms
Storage/Transport Temperature
-25 ... +70 °C
Integrated System Diagnostics Status
Yes
Pull-In Delay After RESET
20 ms
DC Min. Rated Control Voltage
20.4 VDC
DC Max. Rated Control Voltage
253 VDC
Number of NO (Normally Open) Contacts
1
Release Delay on Power Failure
80 ms
Number of NC (Normally Closed) Contacts
2
Pull-In Delay on Automatic Start
100 ms
Number of Undelayed Semiconductor Outputs (with Signal Function)
2